Dual Automatic Temperature Control Module Self-Test
WARNING: This page is about a different car, the 2004 Lincoln Aviator. However, it is still accessible from the selected car via links, so may be relevant.
The DATC module self-test will retrieve on-demand (hard fault) DTCs only, it will not retrieve continuous DTCs. Continuous DTCs can be cleared when exiting the DATC module self-test. Make sure to retrieve continuous DTCs by carrying out the DUAL AUTOMATIC TEMPERATURE CONTROL MODULE - RETRIEVE CONTINUOUS DTCS procedure before clearing any continuous DTCs.
- The DATC module self-test will not detect concerns associated with data link messages like engine coolant temperature or vehicle speed signals. A diagnostic tool must be used to retrieve these concerns.
- The DATC module self-test will detect concerns in the system control functions and will display on -demand (hard fault) DTCs for concerns that are present during the self-test. The vehicle interior temperature should be between 4°C - 38°C (40°F - 100° F) when performing the self-test. If the temperatures are not within the specified ranges, false DTCs may be displayed.
- The self-test can be initiated after cycling the ignition switch from OFF to ON. Normal operation of the climate control system stops when the self-test is activated.
- To enter the self-test press the OFF and FLOOR buttons simultaneously and release, then press the AUTO button within two seconds. The display will show a flashing blower icon for 20 seconds, after which all vacuum fluorescent segments will be displayed if there are no on-demand DTCs present. If DTCs are present the DATC module will display "00 00" and then on -demand DTCs. Record all DTCs displayed.
- If any DTCs appear during the self-test, carry out the diagnostic procedure. Refer to the DUAL/ELECTRONIC AUTOMATIC TEMPERATURE CONTROL (DATC) MODULE DIAGNOSTIC TROUBLE CODE (DTC) INDEX and follow the ACTION for each DTC given.
- If a condition exists but no DTCs appear during the self-test, GO to Symptom Chart Condition: The DATC System Is Inoperative, Intermittent or Incorrect Operation.
- To exit the self-test and RETAIN all continuous DTCs, press any button EXCEPT DEFROST. The DATC module will exit the self-test and retain all continuous DTCs.
- To exit the self-test and CLEAR all continuous DTCs, press the DEFROST button. The DATC module will exit the self -test and all continuous DTCs will be cleared.
- Always exit the self-test before powering the system down (system turned OFF). Once the self-test is exited the ignition switch must remain ON for at least 30 seconds to allow the temperature blend door actuators to automatically recalibrate.
- Continuous DTCs will be deleted after 80 ignition switch ON cycles after the intermittent fault occurs.