Home >> Ford >> 2005 >> Escape Base, 2.3 Z, FWD, Automatic >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Controls (Except Diesel & Hybrid) - Typical Diagnostic Reference Values (Ranger - Town Car) >> Typical Diagnostic Reference Values >> Tarus/Sable >> 3.0L 4V Taurus/Sable
April 5, 2026: LEMON Manuals is launched! Read the announcement.

3.0L 4V Taurus/Sable

Fig 1: 104 Pin PCM - 3.0L 4V Taurus/Sable
G03626777Courtesy of FORD MOTOR CO.
SENSORS/INPUTS - 3.0L 4V TAURUS/SABLE

Sensors/Inputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
TR1 3 10.7  10.7  DCV
SMR 4 VBAT (V)  DCV
TSS 6 43/700  85-105/1480-1570  110-125/1690-2000  Hz/RPM
FRT 10 0.5-3/220-110  0.5-3/220-110  0.5-3/220-110  0.5-3/220-110  DCV/DEG
FEPS 13 0.5-0.6  0.5-0.6  0.5-0.6  0.5-0.6  DCV
PATS IN 17 (S)  (S)  (S)  (S)  (S)
GENLI 20 0-130/0-100 (Q)  Hz/%
CKP 21 390-520  850-1120  1140-1220  Hz
TCS 29 0.1/OFF  VBAT/ON (G)  0.1/OFF  0.1/OFF  DCV/OFF-ON
PSP V/PSP 31 0.1/LOW  VBAT/HIGH (I)  0.1/LOW  0.1/LOW  DCV/LOW-HIGH
HO2S12 35 0.1  (D)  (D)  (D)  DCV
TFT 37 0.5-2/210-110  0.5-2/210-110  0.5-2/210-110  0.5-2/210-110  DCV/DEG
ECT 38 0.4-1/200-160  0.4-1/200-160  0.4-1/200-160  0.4-1/200-160  DCV/DEG
IAT 39 1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  1.7-3.5/120-50 (K)  DCV/DEG
FPM 40 0-7/85-115  0-7/85-115  0-7/85-115  0-7/85-115  DCV/%
ACCS 41 0.1/OFF  VBAT/ON (A)  0.1/OFF  0.1/OFF  DCV/OFF-ON
TR2 49 10.7  10.7  DCV
TR4 50 10.7  10.7  DCV
KS1 57 DCV
IAC-RC 58 VBAT/0  9-10/20-40  8-11.1/34-40 (L)  6-7/45-55 (L)  DCV/%
HO2S11 60 switching (C)  switching (C)  switching (C)  DCV
HO2S22 61 (D)  (D)  (D)  DCV
FTP V/FTP 62 2.6/0.41  2.6/0.41  2.6/0.41  2.6/0.41  DCV/IN-H2O
FRP V/FRP 63 3.15/46  2.74/39  2.88/41  2.86/40  DCV/OFF-ON
TR3 V/TR3 64 4.4/PARK  4.4/PARK  2.1/OD  2.1/OD  DCV/MODE
DPFEGR 65 0.25-1.3  0.25-1.3  0.25-4.65  0.25-4.65  DCV
ACET 66 1.9-4.0  1.9-4.0  1.9-4.0  1.9-4.0  DCV
OSS 84 300/1650  506/2600  Hz/RPM
CMP 85 5-7  10-13  14-17  Hz
ACP V/ACP 86 VBAT/OPEN  VBAT/OPEN  VBAT/OPEN  VBAT/OPEN  DCV/OPEN-CLOSED
HO2S21 87 switching (C)  switching (C)  switching (C)  DCV
MAF V 88 0.5-0.7  0.7-1.5  1.3-2  DCV
TP V 89  0.53-1.27  0.53-1.27  0.8-1.1  1-1.5  DCV
BPP 92 0.1/OFF  VBAT/ON (E)  0.1/OFF  0.1/OFF  DCV/OFF-ON
CPP/PNP PID ON  ON  OFF  OFF  OFF-ON
GEAR PID GEAR
LOAD PID (L)  15-20  20-35  15-35  %
MISF PID OFF  OFF  OFF  OFF  OFF-ON
OCTADJS PID NO RETARD  NO RETARD  NO RETARD  NO RETARD  NO RETARD/RETARD
RPM PID 674-734  1350-1650  1800-2060  RPM
VSS PID 30  55  MPH
ACTUATORS/OUTPUTS - 3.0L 4V TAURUS/SABLE

Actuators/Outputs PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
SSB (SS2) 1 0.1/ON  0.1/ON  VBAT/OFF  0.1/ON  DCV/OFF-ON
CDD (CYL 5) 2 VBAT  VBAT  VBAT  VBAT  DCV
PATS OUT 18 (S)  (S)  (S)  (S)  (S)
CDA (CYL 1) 26 VBAT  VBAT  VBAT  VBAT  DCV
SSA (SS1) 27 VBAT/OFF  VBAT/OFF  0.1/ON  0.1/ON  DCV/OFF-ON
LFC (FC1) 28 VBAT/OFF  0.1/ON (B)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSIL 30 (S)  (S)  (S)  (S)  (S)
MFC (FC2) 42 VBAT/OFF  0.1/ON (B)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
PATSTRT 44 (S)  (S)  (S)  (S)  (S)
GEN RC 45 130/30  130/27  130/23  Hz/%
HFC (FC3) 46 VBAT/OFF  0.1/ON (B)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
EGRVR 47 VBAT/0  VBAT/0  (T)  (T)  DCV/%
CTO 48 33-45  75-85  92-120  Hz
CDB (CYL 4) 52 VBAT  VBAT  VBAT  VBAT  DCV
SSC (SS3) 53 VBAT/OFF  VBAT/OFF  0.1/ON  0.1/ON  DCV/OFF-ON
TCC 54 VBAT/0  VBAT/0  0.2/100  0.2/100  DCV/%
EVMV 56 500-900 (F)  500-900 (F)  mA
EVAPC V 67 VBAT/0  VBAT/0  VBAT/0 (R)  VBAT/0 (R)  DCV/%
VSO 68 65  125  Hz/RPM
ACCR (WAC) 69 VBAT/OFF  0.1/ON (A)  VBAT/OFF  VBAT/OFF  DCV/OFF-ON
INJ5 73 2.2-2.7  2.3-5.5  2-7  mS
INJ3 74 2.2-2.7  2.3-5.5  2-7  mS
INJ1 75 2.2-2.7  2.3-5.5  2-7  mS
CDC (CYL 2) 78 VBAT  VBAT  VBAT  VBAT  DCV
CDE (CYL 3) 79 VBAT  VBAT  VBAT  VBAT  DCV
FP 80 3.6/75  0.1/100  0.1/100  0.1/100  DCV/%
EPC 81 7.5/15  9/15  8.9-10.1/ 16-25  9.2/27  DCV/%
CDF (CYL 6) 82 VBAT  VBAT  VBAT  VBAT  DCV
IAC 83 VBAT/0  9.8-11.2/24-52  7.5-10/24-52 (L)  7.2-8.0/50-59 (L)  DCV/%
HTR11 93 VBAT/OFF  switching  switching  switching  DCV/OFF-ON
HTR21 94 VBAT/OFF  switching  switching  switching  DCV/OFF-ON
HTR12 95 VBAT/OFF  0.2/ON  0.2/ON  0.2/ON  DCV/OFF-ON
HTR22 96 VBAT/OFF  0.2/ON  0.2/ON  0.2/ON  DCV/OFF-ON
INJ6 99 2.2-2.7  2.3-5.5  2-7  mS
INJ4 100  2.2-2.7  2.3-5.5  2-7  mS
INJ2 101 2.2-2.7  2.3-5.5  2-7  mS
LONGFT1 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
LONGFT2 PID (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  (-)20-(+)20  %
SHRTFT1 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 PID (L)  (-)10-(+)10  (-)10-(+)10  (-)10-(+)10  %
SPARKADV PID 12-27  25-42  20-40  DEG
OTHERS - 3.0L 4V TAURUS/SABLE

Other PCM Pin/PID only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (
KAPWR 55 VBAT  VBAT  VBAT  VBAT  DCV
VPWR 71/97 VBAT  VBAT  VBAT  VBAT  DCV
VREF 90 DCV
GENERIC OBD PID VALUES - 3.0L 4V TAURUS/SABLE

NOTE: All generic OBD readings under no load (PARK or NEUTRAL).
PID Hot Idle 2500 RPM Units
LONGFT1 (-)20-(+)20  (-)20-(+)20  %
LONGFT2 (-)20-(+)20  (-)20-(+)20  %
LOAD 30-34  30-40  %
MAF 3.5-4  12-14  G/S
SHRTFT1 (-)10-(+)10  (-)10-(+)10  %
SHRTFT2 (-)10-(+)10  (-)10-(+)10  %
SHRTFT11 (-)10-(+)10  (-)10-(+)10  %
SHRTFT12 95-100  95-100  %
SHRTFT21 (-)10-(+)10  (-)10-(+)10  %
SHRTFT22 95-100  95-100  %
SPARKADV 12-17  35-40  DEG