Ignition Switch Position Run (ISP-R)
The ISP-R provides the PCM with a VBAT input signal from the ignition switch, indicating that the key is either in the ON or START position. When the operator turns the key to the OFF or ACC position, the internal combustion engine immediately ceases to provide power. The PCM coordinates the power down sequence by controlling the power sustain circuit and issuing the proper commands to shut down the electrical system in an orderly fashion, refer to the NORMAL POWER DOWN SEQUENCE . The PCM maintains power to the transaxle control module (TCM) through the power sustain circuit until the power down sequence is complete. The traction battery control module (TBCM) is always powered directly from the low voltage battery which permits wake-up when the vehicle is off.