Pinpoint Test G: The Remote Keyless Entry (RKE) Transmitter Is Out Of Synchronization
NOTE:
All RKE transmitters must be present to begin diagnosis of the RKE system.
- G1 RESYNCHRONIZE THE INOPERATIVE RKE TRANSMITTER
- Key in OFF position.
- Press any button on the inoperative RKE transmitter 4 times consecutively within 30 seconds.
- Does the RKE transmitter operate correctly now?
- Yes : The system is OK. CLEAR the DTCs. TEST the system for normal operation.
- No : GO to G2.
- G2 CHECK FOR A SECOND RKE TRANSMITTER
- Check for another RKE transmitter that operates with the vehicle.
- Is there another RKE transmitter that operates with the vehicle?
- Yes : GO to G3.
- No : GO to G4.
- G3 RESYNCHRONIZE THE INOPERATIVE RKE TRANSMITTER USING THE SECOND RKE TRANSMITTER
- Key in OFF position.
- Press any button on the operational RKE transmitter.
- Within 30 seconds, press a button on the inoperative RKE transmitter.
- Check the inoperative RKE transmitter for correct operation.
- Does the inoperative RKE transmitter operate now?
- Yes : The system is OK. CLEAR the DTCs. TEST the system for normal operation.
- No : GO to G4.
- G4 PROGRAM ALL RKE TRANSMITTERS
- Reprogram the inoperative RKE transmitter individually using a diagnostic tool or reprogram all RKE transmitters using the manual key cycle method. REFER to REMOTE TRANSMITTER PROGRAMMING in this article.
- Does the inoperative RKE transmitter operate now?
- Yes : The system is OK. INFORM the customer that any RKE transmitters not present will need to be reprogrammed. CLEAR the DTCs. TEST the system for normal operation.
- No : To diagnose the inoperative RKE transmitter, Go to PINPOINT TEST C .