LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2005 >> Focus ZX4 ST >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - General Information >> Description And Operation >> Charging System >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Charging System: Notes

The charging system is a negative ground system consisting of the following:

The generator is driven by the accessory drive belt. For additional information, refer to ACCESSORY DRIVE .

When the engine is started, the generator begins to generate alternating current (AC) which is internally converted to direct current (DC). The DC current is controlled by the voltage regulator (located on the rear of the generator), and supplied to the battery.

The charging system voltage is controlled by the powertrain control module (PCM). The generator charges the battery, and at the same time supplies power for all of the electrical loads that are required. The battery is more effectively charged with a higher voltage when the battery is cold and a lower voltage when the battery is warm. The PCM is able to adjust the charging voltage according to the battery temperature by using a signal from the intake air temperature (IAT) sensor. This means the voltage set point is calculated by the PCM and communicated to the regulator by a communication link.

The PCM simultaneously controls and monitors the output of the generator. When the current consumption is high or the battery is discharged, the system is able to increase the idle speed.

To minimize the engine drag when starting the engine, the PCM controls the generator. The generator does not produce any output until the engine has started. The PCM then progressively increases the output of the generator.

The PCM controls the operation of the charging system warning indicator in the instrument cluster. The PCM is responsible for turning the warning indicator off after the engine is started and illuminating it under fault conditions (when the generator is not generating the correct amount of current with the engine running). The warning indicator will also be illuminated by the PCM at key ON engine OFF, and stall conditions.

Units are repaired as an assembly and not disassembled for repair. For additional information, refer to GENERATOR AND REGULATOR .

The battery is a 12-volt DC source connected in a negative ground system. The battery case is sealed with 2 vents to release gases. The battery has 3 main functions:

For additional information, refer to BATTERY, MOUNTING AND CABLES .