Component testing procedure (Wiper/Washer)
MULTIFUNCTION SWITCH - COMPONENT TESTING (WIPER/WASHER)
| Circuit to test | Connect self-powered test light or ohmmeter to terminals | Move switch to these positions | A good switch will indicate |
|---|---|---|---|
| Off | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Off | Open at all cavities. |
| Int-1 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Int-1 | Closed at cavity 4, open at all other cavities |
| Int-2 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Int-2 | Closed at cavities 3 and 4, open at all other cavities. |
| Int-3 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Int-3 | Closed at cavity 3, open at all other cavities. |
| Int-4 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Int-4 | Closed at cavities 3 and 6, open at all other cavities. |
| Int-5 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Int-5 | Closed at cavity 6, open at all other cavities. |
| Low | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Low | Closed at cavities 4 and 6, open at all other cavities. |
| High | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | High | Closed at cavities 1, 4, and 6, open at all other cavities |
| Wash-w/CKT 680 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Wash | Closed at cavity 2, open at cavity 1, any state at other cavities. |
| Wash-w/o CKT 680 | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Wash | Closed at cavities 3, 4, and 6, open at all other cavities |
| Mist | C202c cavity 5 and C202c cavities 1, 2, 3, 4, and 6 | Mist | Closed at cavity 1, open at all other cavities. |