Airflow Mode Door Position
The airflow mode door actuator uses a cam and lever assembly to position the airflow mode doors on command from the HVAC module. The mode door actuator contains a reversible electric motor and potentiometer. The potentiometer allows the HVAC module to monitor the position of the airflow mode doors. The potentiometer circuit consists of a 5-volt reference signal connected to one end of a variable resistor, and a signal ground connected to the other. A signal circuit is connected to a contact wiper, which is driven along the variable resistor by the actuator shaft. The signal to the HVAC module from the contact wiper indicates the position of the airflow mode doors. The HVAC module powers the actuator motor to move the airflow mode doors to the desired position. The HVAC module determines the desired airflow mode door position based on the calculated outlet temperature.
The airflow mode door actuator is located on the heater core and evaporator core housing to the right of the accelerator pedal.