General Specifications
GENERAL SPECIFICATIONS
| Item | Specification |
|---|---|
| Fluid | |
CAUTION: Use only MERCON® V or MERCON® SP transmission fluid. The use of any other fluids may result in transmission failure.
|
|
| 5R55S | |
| MERCON® V Automatic Transmission Fluid XT-5-QM (or XT-5-QMC) (US); CXT-5-LM12 (Canada) | MERCON® V |
| 6R60 | |
| MERCON® SP Automatic Transmission Fluid XT-6-QSP (US); CXT-6-LSP12 (Canada) | MERCON® SP |
| Fluid Capacity | |
| NOTE: Approximate dry capacity, includes cooler and tubes. Transmission Fluid Cooler Flow Test - 5R55S should be used to determine actual fluid requirements and fluid specification. DO NOT OVERFILL. If it is necessary to add or change fluid, use only fluid that has been certified by the supplier as meeting the Ford Motor Company specification shown. | |
| 5R55S | 11.7L (12.4 qt) |
| 6R60 | 11.5L (12.1 qt) |
| Threadlock and Sealer TA-25 | WSK-M2G351-A5 |