Pinpoint Test A: No Communication With The Generic Electronic Module (Gem)
CAUTION:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- A1 CHECK THE GEM CIRCUITS FOR VOLTAGE
- Key in OFF position.
- Disconnect: GEM C201c
- Key in ON position.
- Measure the voltage between the GEM C201c-5, circuit 29-DK20 (OG/GN), harness side and ground; and between the GEM C201c-1, circuit 29-AA17 (OG/WH), harness side and ground.
- Are the voltages greater than 10 volts?
- YES : Go to A2.
- NO : VERIFY the CJB fuse(s) 32 (15A) and 63 (20A) are OK. If OK, REPAIR the circuit in question. CLEAR the DTCs. REPEAT the self-test. CARRY OUT the data link diagnostics test.
- A2 CHECK THE GEM GROUND CIRCUIT 31-DK20 (BK) FOR AN OPEN
- Key in OFF position.
- Disconnect: GEM C201a
- Measure the resistance between the GEM C201a-5, circuit 31-DK20 (BK), harness side and ground.
- Is the resistance less than 5 ohms?
- YES : Go to A3.
- NO : REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test. CARRY OUT the data link diagnostics test.
- A3 CHECK THE GEM GROUND CIRCUIT 91-DK20 (BK/RD) FOR AN OPEN
- Disconnect: GEM C201d
- Measure the resistance between the GEM C201d-1, circuit 91-DK20 (BK/RD), harness side and ground.
- Is the resistance less than 5 ohms?
- YES : REFER to MODULE COMMUNICATIONS NETWORK article to continue communication diagnosis.
- NO : REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test. CARRY OUT the data link diagnostics test.