Control System Outputs - Manual Climate Control
WARNING: This page is about a different car, the 2009 Mercury Grand Marquis and 2009 Ford Crown Victoria. However, it is still accessible from the selected car via links, so may be relevant.
Blower Motor Resistor
The blower motor resistor has the following features:
- The assembly is located in the engine compartment on the evaporator housing toward the center of the vehicle
- Three resistor elements are mounted on the resistor board to provide 4 blower motor speeds
- Depending on the blower motor switch position, series resistance is added or bypassed in the blower motor circuit to decrease or increase blower motor speed
- A device to prevent overheating (thermal limiter) will open the resistor coil when the temperature reaches 121°C (250°F) interrupting the blower motor operation in all speeds except HI
- The thermal limiter cannot be reset and is not serviceable
Temperature Blend Door Actuator
The temperature blend door actuator is located on the top of the plenum housing.
- Its function is to move the temperature blend door to the position indicated on the temperature control switch.
- The temperature blend door actuator contains a reversible electric motor.
Vacuum Control Motors
Vacuum control motors are used to move the floor/panel, panel/defrost and air inlet mode doors.