LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2009 >> Edge SE, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1115 (Climate Control System - General Information And Diagnostics) >> Diagnostic Tests >> Climate Control System >> Symptom Chart
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Symptom Chart

WARNING: This page is about a different car, the 2007 Lincoln MKX and 2007 Ford Edge. However, it is still accessible from the selected car via links, so may be relevant.
SYMPTOM CHART

Condition Possible Sources Action
  • No communication with the electronic automatic temperature control (EATC) module
  • Fuse(s)
  • Circuitry open
  • EATC module communication network
  • Air inlet door is inoperative
  • Circuitry open/shorted
  • EATC module
  • Electronic manual temperature control (EMTC) module
  • Air inlet door actuator/linkage
  • Incorrect/erratic direction of airflow from outlets
  • Circuitry short/open
  • Door actuator
  • Defrost/panel/floor door actuator/linkage
  • LH or RH blend door actuator/linkage
  • EMTC or EATC module
  • The temperature control is inoperative/does not operate correctly
  • Circuitry open/shorted
  • Door actuator
  • LH or RH blend door actuator/linkage
  • EMTC or EATC module
  • The EATC system is inoperative, intermittent or incorrect operation
  • Fuse(s)
  • Circuitry open
  • Insufficient, erratic or no heat
  • Low engine coolant level
  • Engine overheating
  • Plugged or partially plugged heater core
  • Temperature blend door is binding or stuck
  • Temperature blend door actuator
  • Heater hose is kinked or binding
  • The air conditioning (A/C) is inoperative/does not operate correctly
  • Open fuse
  • Circuitry short/open
  • PCM
  • EMTC or EATC module
  • A/C compressor
  • A/C control relay
  • A/C evaporator temperature sensor
  • A/C pressure transducer
  • Battery junction box (BJB)
  • The air conditioning (A/C) is always on
  • Circuitry shorted
  • PCM
  • EMTC or EATC module
  • A/C compressor
  • A/C control relay
  • A/C evaporator temperature sensor
  • A/C pressure transducer
  • The blower motor is inoperative - EMTC
  • Fuse(s)
  • Circuitry open
  • A/C blower motor switch
  • Blower motor relay
  • A/C blower motor
  • EMTC module
  • The blower motor does not operate correctly - EMTC
  • Circuitry open/shorted
  • A/C blower motor resistor
  • A/C blower motor switch
  • The blower motor is inoperative - EATC
  • Fuse(s)
  • Circuitry open/shorted
  • Blower motor relay
  • A/C blower motor
  • EATC module
  • Blower motor speed control
  • The blower motor does not operate correctly - EATC
  • Circuitry open/shorted
  • Blower motor speed control
  • EATC module
  • A/C blower motor relay
  • The steering wheel control switch is inoperative/does not operate correctly
  • Circuitry open/shorted
  • Steering wheel control switch
  • EATC module
  • The dual temperature control is inoperative/does not operate correctly
  • Temperature blend door/actuator broken/binding
  • EATC module
  • Low A/C refrigerant charge
  • CHECK that the A/C system pressure is above 290 kPa (42 psi). If the pressure is below 290 kPa (42 psi), REFER to Fluorescent Dye Leak Detection . CHECK the temperature blend doors/actuators for a binding or broken condition. If no condition is found, INSTALL a new EATC module.
  • The temperature set point does not repeat after turning the ignition switch OFF
  • Open fuse
  • Circuitry short/open
  • EATC module
  • CHECK circuit SBP15 (WH/RD) for a short or open and repair as necessary. If OK, INSTALL a new EATC module.
  • The temperature display will not switch between Celsius and Fahrenheit
  • EATC module
  • Instrument cluster module
  • If the instrument cluster does not switch between English and Metric, REFER to INSTRUMENT CLUSTER AND PANEL ILLUMINATION .
  • If only the EATC module does not switch between English and Metric, INSTALL a new EATC module.
  • Inaccurate external temperature display
  • EATC module
  • Ambient temperature sensor
  • REFER to Description and Operation of the EATC External Temperature Display. If the external temperature display is not operating as described and no DTC is present, CARRY OUT the Ambient Temperature Sensor . If the sensor tests OK, CARRY OUT the Electronic Automatic Temperature Control (EATC) module and Electronic Manual Temperature Control (EMTC) module cold boot process. If the condition returns, INSTALL a new EATC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.