3-Track APP Sensor
There are 3 pedal position signals in the sensor. Signal 1, APP, has a negative slope (increasing angle, decreasing voltage) and signals 2 and 3, APP2 and APP3, both have a positive slope (increasing angle, increasing voltage). During normal operation, APP is used as the indication of pedal position by the strategy. The 3 pedal position signals make sure the PCM receives a correct input even if one signal has a concern. The PCM determines if a signal is incorrect by calculating where it should be, inferred from the other signals. If a concern is present with one of the circuits the other inputs are used. The pedal position signal is converted to pedal travel degrees (rotary angle) by the PCM. The software then converts these degrees to counts, which is the input to the torque based strategy. There are 2 reference voltage circuits, 2 signal return circuits, and 3 signal circuits (a total of 7 circuits and pins) between the PCM and the APP sensor assembly.