LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2011 >> Crown Victoria Base, 4.6 V >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Charging System: Specifications

GENERAL SPECIFICATIONS

Item Specification
Generator (Base Vehicle) 
Generator pulley ratio 2.72:1
Rating 82 amps @ 500 rpm (min) - 140 amps @ 2,000 rpm (max)
Voltage regulator type Electronic internal with generator
Generator (Police Interceptor/Long Wheel Base (LWB) Taxi) 
Generator pulley ratio 2.95:1
Rating 95 amps @ 500 rpm (min) - 195 amps @ 2,000 rpm (max)
Voltage regulator type Electronic internal with generator
TORQUE SPECIFICATIONS

Description Nm lb-ft lb-in
Engine cover nut 10 - 89
Generator B+ cable nut 12 - 106
Generator bolts 25 18 -
Generator bracket bolts 10 - 89
Generator radial adapter nut 10 - 89