Electric Exhaust Gas Recirculation (EEGR) System Monitor: Notes
The EEGR system monitor is an on board strategy designed to test the integrity and flow characteristics of the EGR system. The EEGR system monitor consists of an electrical and functional test that checks the stepper motor and the EEGR system for correct flow. The powertrain control module (PCM) controls the EEGR valve by commanding from 0 to 52 discrete increments or steps to get the valve from the fully closed position to the fully open position. The stepper motor electrical test is a continuous check of the 4 electric stepper motor coils and circuits to the PCM. A concern is indicated if an open circuit, short to voltage, or short to ground has occurred in one or more of the stepper motor coils or circuits for a calibrated period of time. If a concern has been detected, the EEGR system is disabled, setting diagnostic trouble code (DTC) P0403. Additional monitoring is suspended for the remainder of the drive cycle, or until the next engine startup.
The EEGR system monitor can be calibrated to use either an intrusive or non-intrusive diagnostic depending on calibration. Both diagnostics are based off of a change in intake manifold pressure during engine operating conditions including EGR flow versus conditions without EGR flow.