Programming the Autolock Feature
NOTE:
The autolock feature can be activated or deactivated independently of the auto-unlock feature.
NOTE:
The autolock feature of the Smart Junction Box (SJB) can also be configured on or off with the scan tool. For additional information on module configuration, refer to
MODULE CONFIGURATION SYSTEM
article.
NOTE:
When programming the autolock feature using the door lock control switch method, the following steps must be carried out within 30 seconds or the procedure needs to be repeated. If the procedure needs to be repeated, wait 30 seconds between programming sessions.
- Turn the ignition key from the OFF to the RUN position.
- Press the UNLOCK button on the door lock control switch 3 times.
- Turn the ignition key from the RUN to the OFF position.
- Press the UNLOCK button on the door lock control switch 3 times.
- Turn the ignition key to the RUN position. The horn chirps to indicate that programming mode is entered.
- To enable/disable the autolock feature, press the UNLOCK button on the door lock control switch then the LOCK button. The horn chirps once if the autolocks are disabled or twice (one short chirp followed by a long chirp) if the autolocks are enabled.
- Turn the ignition key to the OFF position. The horn chirps once to signal that the programming is complete.