Pinpoint Test O: Traction Control System Cannot Be Disabled
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- O1 CHECK FOR COMMUNICATION DTCs
- Check for any ABS module communication DTCs.
- Is DTC U0155:00 present?
- Yes: GO to PINPOINT TEST L .
- No: GO to O2 .
- O2 CHECK THE STABILITY TRACTION CONTROL SWITCH STAB_CTRL_SW PID
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: IPC DataLogger.
- Access the IPC PID STAB_CTRL_SW.
- Monitor the PID STAB_CTRL_SW while pressing and releasing the traction control switch.
- Does the PID STAB_CTRL_SW show the traction control switch changing from on to off?
- Yes: The system is operating correctly at this time.
- No: GO to O3 .
- O3 CHECK THE STABILITY TRACTION CONTROL SWITCH
- Ignition OFF.
- Disconnect: Stability/Traction Control Switch C2267.
- Measure the resistance between the traction control switch pin 7, component side, and pin 1, component side while pressing and releasing the switch.
- Is the resistance greater than 10,000 ohms with the switch released and less than 5 ohms with the switch pressed?
- Yes: GO to O4 .
- No: INSTALL a new hazard flasher lamp switch. REFER to EXTERIOR LIGHTING SYSTEM article. TEST the system for normal operation.
- O4 CHECK STABILITY/TRACTION CONTROL CIRCUIT FOR AN OPEN
- Measure the resistance between hazard flasher lamp switch C2267-7, circuit CCA15 (YE/GY), harness side and IPC C220-7, circuit CCA15 (YE/GY), harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to O5 .
- No: REPAIR circuit CCA15 (YE/GY) for an open. TEST the system for normal operation.
- O5 CHECK STABILITY/TRACTION CONTROL CIRCUIT FOR A SHORT TO GROUND
- Measure the resistance between hazard flasher lamp switch C2267-7, circuit CCA15 (YE/GY), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- Yes: GO to O6 .
- No: REPAIR circuit CCA15 (YE/GY) for a short to ground. TEST the system for normal operation.
- O6 CHECK GROUND CIRCUIT FOR AN OPEN
- Disconnect: Negative Battery Cable.
- Measure the resistance between hazard flasher lamp switch C2267-1, circuit GD116 (BK/VT), harness side and ground.
- Is the resistance less than 5 ohms?
- Yes: GO to O7 .
- No: REPAIR circuit GD116 (BK/VT) for an open. TEST the system for normal operation.
- O7 CHECK THE IPC CONNECTOR
- Ignition OFF.
- Check IPC
connector for:
- corrosion
- damaged pins
- pushed-out pins
- Connect the IPC connector and make sure that it is seated correctly.
- Make sure the connector is seated correctly then operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new IPC . REFER to INSTRUMENTATION SYSTEM, MESSAGE CENTER & WARNING CHIMES article. TEST the system for normal operation.
- No: The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector.