Transmission Control Module (TCM): Installation
- Install the TCM and the 2 nuts.
- Tighten to 20 Nm (177 lb-in).
- Connect the TCM electrical connector and slide the lock tab down to lock the connector.
- Restore the module configuration. Carry out the module configuration restore steps of the Programmable Module Installation (PMI) procedure. For additional information, refer to MODULE CONFIGURATION .
- Using the scan tool, download the solenoid body strategy. For additional information, refer to SOLENOID BODY STRATEGY .
NOTE:
Keep the Transmission Control Module (TCM) electrical connector straight when connecting it or damage the connector terminals can occur.