- No communication with the HVAC
module
|
- Fuse(s)
- Wiring, terminals or connectors
- HVAC
system and/or related components
|
|
- Climate control system functional test
|
- HVAC
system and/or related components
|
|
|
|
- Wiring, terminals or connectors
- A/C compressor clutch air gap
- A/C pressure transducer
- Evaporator temperature sensor
- A/C clutch relay
- Blower motor
- Blower motor control
- PCM
|
|
- The air inlet door is inoperative
|
- Wiring, terminals or connectors
- Air inlet mode door actuator
- Air inlet mode door binding or stuck
- HVAC
module
- FCIM
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Wiring, terminals or connectors
- Defrost/panel/floor mode door actuator
- Defrost/panel/floor mode door binding or stuck
- HVAC
module
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Plugged or partially plugged heater core
- Temperature blend door(s) binding or stuck
- Temperature blend door actuator(s)
- HVAC
module
|
|
|
|
- Fuse(s)
- Wiring, terminals or connectors
- A/C system discharged/low charge
- A/C system discharged/low charge
- HVAC
module
- PCM
- FCIM
- A/C clutch relay
- A/C compressor clutch air gap
- A/C pressure transducer
- Evaporator temperature sensor
- A/C compressor clutch field coil
|
|
- The A/C operation is erratic. The discharge air warms up when the vehicle comes to a stop.
|
- Engine cooling fan relay
- Engine cooling fan
- PCM
|
|
- The A/C is always on - A/C compressor does not cycle
|
- Wiring, terminals or connectors
- PCM
- A/C clutch relay
- A/C compressor clutch air gap
- Evaporator temperature sensor
|
|
- The A/C is always on - A/C mode always commanded ON
|
- Wiring, terminals or connectors
- HVAC
module
- PCM
- FCIM
|
|
- Temperature control is inoperative/does not operate correctly
|
- Wiring, terminals or connectors
- HVAC
module
- Temperature blend door is binding or stuck
- Temperature blend door actuator
- FCIM
|
|
- The blower motor is inoperative
|
- Fuse(s)
- Wiring, terminals or connectors
- Blower motor relay
- Blower motor
- HVAC
module
- Blower motor speed control
- FCIM
|
|
- The blower motor does not operate correctly
|
- Wiring, terminals or connectors
- Blower motor speed control
- HVAC
module
- FCIM
|
|
- A/C pressure relief valve discharging
|
- High system pressure
- A/C pressure relief valve
|
|