Contaminated Refrigerant Handling

WARNING: This page is about a different car, the 2015 Lincoln MKT. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: If contaminated refrigerant is detected, DO NOT recover the refrigerant into R-134a recovery/recycling equipment. Recovery of contaminated refrigerant contaminates the recovered refrigerant supply and may damage the recovery/recycling equipment.
NOTE: Install a new suction accumulator, receiver drier or receiver drier element as directed by the A/C system flushing procedure.

  1. 1.

    Recover the contaminated refrigerant using suitable recovery-only equipment designed for capturing and storing contaminated refrigerant only.

  1. 2.

    Determine and correct the cause of the customer's initial concern.

  1. 3.

    Refer to Air Conditioning (A/C) System Flushing .

  1. 4.

    Dispose of the contaminated refrigerant in accordance with all federal, state and local regulations.