- No communication with the HVAC module
|
- Fuse(s)
- Circuitry open
- HVAC module communication network
|
|
- Unable to duplicate the customer concern and no DTCs present
|
- HVAC system and/or related components
|
|
- Incorrect/erratic function in AUTO mode
|
- Circuitry open/shorted
- In-vehicle temperature sensor
- HVAC module
|
|
|
|
|
|
- A/C compressor clutch air gap
- A/C pressure transducer
- Evaporator discharge air temperature sensor
- A/C clutch relay
- Blower motor
- Blower motor control
- PCM
|
|
- The air inlet door is inoperative
|
- Circuitry open/shorted
- Air inlet mode door actuator
- Air inlet door binding or stuck
- HVAC module
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Circuitry open/shorted
- Mode door actuator(s)
- Mode door(s) binding or stuck
- HVAC module
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Plugged or partially plugged heater core
- Temperature blend door(s) binding or stuck
- Temperature blend door actuator(s)
|
|
- The air conditioning (A/C) is inoperative
|
- Fuse(s)
- Circuitry open
- A/C system discharged/low charge
- PCM
- HVAC module
- A/C clutch relay
- A/C compressor clutch air gap
- A/C pressure transducer
- Evaporator discharge air temperature sensor
- A/C compressor clutch field coil
|
|
- The air conditioning (A/C) is always on - A/C compressor does not cycle
|
- Circuitry shorted
- PCM
- A/C clutch relay
- A/C compressor clutch air gap
- Evaporator discharge air temperature sensor
|
|
- The air conditioning (A/C) is always on - A/C mode always commanded ON
|
- Circuitry shorted
- PCM
- HVAC module
|
|
- Temperature control is inoperative/does not operate correctly
|
- Circuitry open/shorted
- HVAC module
- Temperature blend door is binding or stuck
- Temperature blend door actuator
|
|
- The blower motor is inoperative
|
- Fuse(s)
- Circuitry short/open
- Blower motor relay
- Blower motor
- HVAC module
- Blower motor speed control
|
|
- The blower motor does not operate correctly
|
- Circuitry open/shorted
- Blower motor speed control
- HVAC module
|
|
- The temperature set point does not repeat after turning the ignition switch OFF
|
|
|
- Inaccurate external temperature display
|
- HVAC module
- Ambient temperature sensor
|
|
- A/C pressure relief valve discharging
|
- High system pressure
- A/C pressure relief valve
|
- CHECK the high side system pressure. If the pressure is below the A/C pressure relief valve open pressure, REPLACE the A/C pressure relief valve. If the system pressure is above the A/C pressure relief valve open pressure, REPAIR the system for a restriction.
|