Max A/C
When MAX A/C mode is selected:
- the air inlet door closes, preventing outside air and allowing only recirculated air.
- the recirculated air indicator is illuminated (recirculated air forced on).
- the mode doors direct airflow to the instrument panel registers.
- the temperature door moves to the full cool position. Air temperature can be manually overridden.
- the A/C button is illuminated.
- the A/C compressor operates if the outside temperature is above approximately -2.2°C (28.4°F).
- the blower motor is commanded to the highest speed. The blower motor speed is adjustable.