Engine Running Load Shed
When the BCM and/or PCM voltage is low, with the engine running, the BCM sends a message to either minimize or shut down the climate controlled seats, rear defrost, heated mirrors and climate control blower motor to improve system voltage. Under this condition, the IPC message center displays LOW BATTERY FEATURES TEMPORARILY TURNED OFF to notify the driver that battery protection actions are active during a Load Shed 2 continuous event.
There are 3 states of engine running load shed:
- Load shed 1
- Load shed 2 transient
- Load shed 2 continuous
| Load Shed State | Entry Conditions | Impact to Features | Clear Conditions |
|---|---|---|---|
| Load shed 1 |
|
If equipped, the climate controlled seats will switch from HIGH to MED. If they are already at MED, the state will not change. | Voltage to the BCM is greater than 12.7 volts or the generator field duty cycle is less than 88%. |
| Load shed 2 transient |
|
|
Voltage to the BCM is greater than 12.4 volts. |
| Load shed 2 continuous | Vehicle was in load shed 2 transient state for greater than 20 seconds. |
|
Voltage to the BCM is greater than 12.4 volts for more than 60 seconds. |