Pinpoint Test L : B1B71:11, B1B71:15: Notes
WARNING: This page is about a different car, the 2016 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
Refer to Manual Climate Control System for schematic and connector information.
Normal Operation and Fault Conditions
Evaporator Temperature Sensor, REFER to: Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC) - System Operation and Component Description .
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1B71:11 | Evaporator Temperature Sensor: Circuit Short To Ground | The module senses excessive voltage drop on the sensor reference voltage circuit, indicating a short directly to ground. The module defaults to calculated evaporator temperature and the compressor is shut off. |
| B1B71:15 | Evaporator Temperature Sensor: Circuit Short To Battery or Open | The module senses no voltage drop on the sensor reference voltage circuit, indicating a short directly to voltage or an open circuit. The module defaults to calculated evaporator temperature and the compressor is shut off. |
Possible Sources
- Wiring, terminals or connectors
- Evaporator temperature sensor
- FCIM