General Specifications 

Item Specification
2.7L EcoBoost, 3.5L Duratec and 3.5L EcoBoost without climate controlled seats or Alternating Current (AC) power outlet socket - 200 amp 
Generator pulley ratio 2.67:1
Rating 130 amps at 675 rpm (min) to 200 amps at 2, 250 rpm (max)
Voltage regulator type Electronic internal with generator
2.7L EcoBoost, 3.5L Duratec and 3.5L EcoBoost with climate controlled seats or Alternating Current (AC) power outlet socket - 240 amp 
Generator pulley ratio 2.67:1
Rating 140 amps at 675 rpm (min) to 240 amps at 2, 250 rpm (max)
Voltage regulator type Electronic internal with generator
5.0L Ti-VCT without climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 200 amp 
Generator pulley ratio 2.81:1
Rating 130 amps at 640 rpm (min) to 200 amps at 2, 135 rpm (max)
Voltage regulator type Electronic internal with generator
5.0L Ti-VCT with climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 240 amp 
Generator pulley ratio 2.81:1
Rating 140 amps at 640 rpm (min) to 240 amps at 2, 135 rpm (max)
Voltage regulator type Electronic internal with generator