Pinpoint Test M : B1B71:21, B1B71:22, B1B71:2F: Notes
Refer to MANUAL CLIMATE CONTROL SYSTEM for schematic and connector information.
Normal Operation and Fault Conditions
Evaporator temperature sensor, REFER to: Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC) - System Operation and Component Description
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1B71:21 | Evaporator Temperature Sensor: Signal Amplitude < Minimum | This Continuous Memory Diagnostic Trouble Code (CMDTC) and on-demand DTC sets when the BCM senses lower than expected voltage from the evaporator temperature sensor. |
| B1B71:22 | Evaporator Temperature Sensor: Signal Amplitude > Maximum | This Continuous Memory Diagnostic Trouble Code (CMDTC) sets when the BCM senses greater than expected voltage from the evaporator temperature sensor. |