Pinpoint Test S : The Power Point Is Never / Always Powered: Notes
Refer to HORN/CIGAR LIGHTER for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Module Controlled Functions - System Operation and Component Description .
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1430:12 | Power Point Relay Reset Output: Circuit Short To Battery | A continuous and on-demand DTC that sets when the BCM detects a short to voltage from the power point relay coil circuit. |
| B1430:14 | Power Point Relay Reset Output: Circuit Short To Ground or Open | A continuous and on-demand DTC that sets when the BCM detects a short to ground or open from the power point relay coil circuit. |
| B1435:12 | Power Point Relay Set Output: Circuit Short To Battery | A continuous and on-demand DTC that sets when the BCM detects a short to voltage from the power point relay coil circuit. |
| B1435:14 | Power Point Relay Set Output: Circuit Short To Ground or Open | A continuous and on-demand DTC that sets when the BCM detects a short to ground or open from the power point relay coil circuit. |
Possible Sources
- Power point
- BCM
- BJB
- Power point
- Wiring, terminals or connectors
Visual Inspection and Diagnostic Pre-Checks
Inspect BJB fuse 5 (20A), fuse 10 (20A), fuse 16 (20A) and fuse 17 (20A).