Typical Diagnostic Reference Values

Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
APP APP Sensor 0 0 15.5 26.5 %
APP1 APP Sensor 0.74 0.74 1.25 1.36 VOLTS
APP2 APP Sensor 0.36 0.37 0.63 0.68 VOLTS
B+ PID 12.4 13-14 13-14 13-14 VOLTS
BARO PID 14.3/156.2 14.3/156.2 14.05/154.7 14.3/156.2 PSI/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
CHT CHT Sensor 0.61/89 (192.2) 0.6/90 (194) 3.58/94 (201.2) 3.56/96 (204.8) VOLTS/DEG C (DEG F)
ETC_TRIM PID 0.39(J) 0.43(J) 0.36(J) 0.36(J) DEG
FPM Fuel Pump Control Module 60.25 60.35 60.25 60.31 %
FTP FTP Sensor 2.6/0 2.6/0 2.3/-0.07 2.1/-0.11 VOLTS/PSI
IAT IAT Sensor 2.9/22.7 (73) 3.3/15 (59) 3.7/7.2 (45) 3.7/6.1 (43) VOLTS/DEG C (DEG F)
KNOCK_1 KS1 Sensor 0 0 301 525 N/A
KNOCK_2 KS2 Sensor 0 0 289 448 N/A
LOAD PID 0 (I) 20 41 56 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0/697 8/2.52 30/4.27 58/5.46 g/s/Hz
MISFIRE PID NO NO NO NO YES/NO
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S12 HO2S12 Sensor (I) (D) (D) (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
PTO PID OFF OFF OFF OFF ON/OFF
PTOIR_V PID 0.02 0.02 0.02 0 VOLTS
PTOLOAD PID OFF OFF OFF OFF ON/OFF
RPM CKP Sensor 0 654 1127 1618 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EVAPCP EVAPCP Valve 0 0 0 99.9 %
EVAPCV CANV Valve 0 0 0 0 %
FP Fuel Pump Control Module 75 31 31 31 %
IMTV IMTV Solenoid 0 0 0 0 %
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 22 36 30 21 %
O2S21_HTR HO2S21 Sensor 22 36 29 21 %
PTOIL PTO Lamp OFF OFF OFF OFF ON/OFF
SPARKADV PID 13.50 12.25 27.75 32 DEG
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS