Gateway Module A (GWM): Removal
WARNING: This page is about a different variant/trim than selected.
NOTE:
Removal steps in this procedure may contain installation details.
-
NOTE: If installing a new module, it is necessary to upload the module configuration information to the scan tool prior to removing the module. This information must be downloaded into the new module after installation.
Upload the GWM configuration to the scan tool by following the scan tool on-screen instructions.
- Remove the nuts and the GWM. Disconnect the electrical connector.
Torque: 27 lb.in (3 Nm)