Pinpoint Test L : B10B5:11, B10B5:15, B10B6:11, B10B6:15: Notes
WARNING: This page is about a different car, the 2017 Ford Edge. However, it is still accessible from the selected car via links, so may be relevant.
Refer to MANUAL CLIMATE CONTROL SYSTEM for schematic and connector information.
Normal Operation and Fault Conditions
The air discharge temperature sensors contains a thermistor. The sensor varies its resistance with the temperature. As the temperature rises, the resistance falls. As the temperature falls, the resistance rises.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B10B5:11 | Left Panel Air Discharge Temperature: Circuit Short To Ground | This DTC sets when the FCIM senses erratic voltages from the left panel air discharge temperature sensor. |
| B10B5:15 | Left Panel Air Discharge Temperature: Circuit Short To Battery or Open | This DTC sets when the FCIM senses erratic voltages from the left panel air discharge temperature sensor. |
| B10B6:11 | Left Floor Air Discharge Temperature: Circuit Short To Ground | This DTC sets when the FCIM senses erratic voltages from the left floor air discharge temperature sensor. |
| B10B6:15 | Left Floor Air Discharge Temperature: Circuit Short To Battery or Open | This DTC sets when the FCIM senses erratic voltages from the left floor air discharge temperature sensor. |
Possible Sources
- Wiring, terminals or connectors
- Air discharge temperature sensor(s)
- FCIM