Typical Diagnostic Reference Values
WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2016 Lincoln Navigator, 2016 Lincoln MKZ, 2016 Lincoln MKX, 2016 Lincoln MKT, and 2016 Lincoln MKS. However, it is still accessible from the selected car via links, so may be relevant.
| Inputs |
Component/PID Only |
Measured/PID Values |
Units Measured/PID |
| KOEO |
Hot Idle |
48 KM/H (30 MPH) |
89 KM/H (55 MPH) |
| APP |
APP Sensor |
0 |
0 |
18 |
23.5 |
% |
| APP2 |
APP Sensor |
0.39 |
0.39 |
0.49 |
0.92 |
VOLTS |
| APP_MAXDIFF |
PID |
0 |
0 |
0 |
-0.06 |
DEG |
| B+ |
PID |
12.7 |
13-14 |
13-14 |
13-14 |
VOLTS |
| BARO |
PID |
14.35/155.2 |
14.35/155.2 |
14.35/155.2 |
14.35/155.2 |
PSI/Hz |
| BOO |
BPP Switch |
OFF |
ON (E) |
OFF |
OFF |
ON/OFF |
| ECT |
ECT Sensor |
3.27/105 (221) |
3.51/97 (206.6) |
3.9/84 (183.2) |
3.78/88 (190.4) |
VOLTS/DEG C (DEG F) |
| HTRCM11 |
HO2S11 Sensor |
1.65 |
1.65 |
1.65 |
1.48 |
AMPS |
| HTRCM12 |
HO2S12 Sensor |
615 |
615 |
615 |
622 |
mA |
| IAT |
IAT Sensor |
1.27/62 (143.6) |
1.79/49 (120.2) |
3.42/16 (60.8) |
4.04/2 (35.6) |
VOLTS/DEG C (DEG F) |
| LOAD |
PID |
0 (I) |
27.45 |
29.41 |
44.31 |
% |
| MAP |
MAP Sensor |
4.02/98.93/14.35/29.2 |
1.25/30.95/4.49/9.2 |
2.52/61.98/8.99/17.8 |
2.32/51.98/7.54/15.4 |
VOLTS/kPa/PSI/inHg |
| MISFIRE |
PID |
NO |
NO |
NO |
NO |
YES/NO |
| MP_LRN |
PID |
NO |
NO |
NO |
NO |
YES/NO |
| O2BANK1 |
PID |
VARIES |
VARIES |
VARIES |
VARIES |
RICH/LEAN |
| O2S11 |
HO2S11 Sensor |
(I) |
switching (C) |
switching (C) |
switching (C) |
VOLTS |
| O2S12 |
HO2S12 Sensor |
(I) |
(D) |
(D) |
(D) |
VOLTS |
| RPM |
CKP Sensor |
0 |
698.3 |
1918 |
1807 |
RPM |
| SYNC |
PID |
NO |
YES |
YES |
YES |
YES/NO |
| VSS |
PID |
0 |
0 |
48 km/h (30 MPH) |
89 km/h (55 MPH) |
km/h/MPH |
| Outputs |
Component/PID Only |
Measured/PID Values |
Units Measured/PID |
| KOEO |
Hot Idle |
48 KM/H (30 MPH) |
89 KM/H (55 MPH) |
| EVAPCP |
EVAPCP Valve |
OFF |
OFF |
ON |
ON |
ON/OFF |
| FP |
Fuel Pump Control Module |
OFF |
ON |
ON |
ON |
ON/OFF |
| FUELSYS |
PID |
OPEN LOOP |
CLOSED LOOP |
CLOSED LOOP |
CLOSED LOOP |
OPEN/CLOSED LOOP |
| HFC |
PID |
OFF |
ON (B) |
OFF |
OFF |
ON/OFF |
| HTR11 |
HO2S11 Sensor |
OFF |
ON |
ON |
ON |
ON/OFF |
| HTR12 |
HO2S12 Sensor |
OFF |
ON |
ON |
ON |
ON/OFF |
| IMRC |
IMRC Solenoid |
OFF |
ON |
ON |
ON |
ON/OFF |
| IMTV |
IMTV Solenoid |
OFF |
ON |
ON |
ON |
ON/OFF |
| LFC |
PID |
OFF |
ON (B) |
OFF |
OFF |
ON/OFF |
| LONGFT1 |
PID |
(I) |
-20 TO +20 |
-20 TO +20 |
-20 TO +20 |
% |
| SHRTFT1 |
PID |
(I) |
-10 TO +10 |
-10 TO +10 |
-10 TO +10 |
% |
| SPARKADV |
PID |
10 |
10.25 |
39 |
27.25 |
DEG |
| Other |
Component/PID Only |
Measured/PID Values |
Units Measured/PID |
| KOEO |
Hot Idle |
48 KM/H (30 MPH) |
89 KM/H (55 MPH) |
| VPWR |
PID |
12.52 |
13-14 |
13-14 |
13-14 |
VOLTS |
| VREF |
PID |
5 |
5 |
5 |
5 |
VOLTS |