Section 653 (Generator And Regulator): Specifications: Specifications
WARNING: This page is about a different car, the 2017 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
General Specifications
| Item | Specification |
|---|---|
| 2.7L EcoBoost, 3.5L Duratec and 3.5L EcoBoost without climate controlled seats or Alternating Current (AC) power outlet socket - 200 amp | |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Rating | 130 amps at 675 RPM (min) to 200 amps at 2, 250 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 2.7L EcoBoost, 3.5L Duratec and 3.5L EcoBoost with climate controlled seats or Alternating Current (AC) power outlet socket - 240 amp | |
| Generator pulley ratio | 2.67:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | OAD |
| Rating | 130 amps at 675 RPM (min) to 240 amps at 2, 250 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 5.0L Ti-VCT without climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 200 amp | |
| Generator pulley ratio | 2.81:1 |
| Generator pulley replaceable | No |
| Generator pulley type | Solid |
| Rating | 130 amps at 640 RPM (min) to 200 amps at 2, 135 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 5.0L Ti-VCT with climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 240 amp | |
| Generator pulley ratio | 2.81:1 |
| Generator pulley replaceable | No |
| Generator pulley type | Solid |
| Rating | 130 amps at 675 RPM (min) to 240 amps at 2, 250 RPM (max) |
| Voltage regulator type | Electronic internal with generator |