Home >> Ford >> 2017 >> Mustang V6, 2D Convertible, Standard Trans >> Repair and Diagnosis (Single Page) >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System - General Information >> Diagnosis And Testing >> Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC) >> Pinpoint Test(s) >> Pinpoint Test L : B1B71:11, B1B71:15 >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Pinpoint Test L : B1B71:11, B1B71:15: Notes

Refer to Manual Climate Control System for schematic and connector information.

Normal Operation and Fault Conditions 

Evaporator Temperature Sensor, REFER to: Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC) - System Operation and Component Description .

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Conditions
B1B71:11 Evaporator Temperature Sensor: Circuit Short To Ground The module senses excessive voltage drop on the sensor reference voltage circuit, indicating a short directly to ground. The module defaults to calculated evaporator temperature and the compressor is shut off.
B1B71:15 Evaporator Temperature Sensor: Circuit Short To Battery or Open The module senses no voltage drop on the sensor reference voltage circuit, indicating a short directly to voltage or an open circuit. The module defaults to calculated evaporator temperature and the compressor is shut off.