Accessory Protocol Interface Module (APIM) Programming

For information on Ford Color Coded Illustrations refer to OEM Color Coding .

Special Tool(s)

GFD342420Courtesy of FORD MOTOR COMPANY
SYNC RE-FLASH KIT
CCMSYNC-KIT or equivalent

Accessory Protocol Interface Module(APIM) Programming Using the Integrated Diagnostic System(IDS) 

  1. NOTE: The IDS program must be closed before attempting to program the APIM.

    Open a session for the vehicle from the technician service publication web site, and run OASIS using "Read VIN and DTC's".

  2. From the OASIS tab, select the "SYNC" button.
  3. There are 3 available options for APIM programming:

    • Standard (latest version of current software and applications): Use this option to update the APIM to the latest software level.

    • Custom (show what's available, and let me choose): Use this option to show all the available options that can be programmed, or if a TSB directs for specific software version to be programmed.

    • Module Replacement (restore software for newly installed hardware): Use this option when the APIM has been replaced.

  4. After selecting 1 of the 3 options (Standard, Custom or Module Replacement), click the "Read SYNC" button to verify the current APIM, VIP and CIP software levels.

    • The versions are compared to a online database. After the comparison, the available software is displayed.

  5. NOTE: Do not disconnect the VCM or the USB cable during APIM programming.

    When carrying out the programming procedures, follow the scan tool on-screen directions.

    NOTE: If unable to complete programming because operation stops or errors are received, interned browser settings may need to be configured. From the on-line OASIS tab, select the "Service Tips" tab, then select "SYNC Software Programming" under "Job Aids".

    Select the "Program SYNC" button to begin the APIM programming process.

  6. Follow the scan tool on-screen directions for APIM programming.

    • After programming is complete the scan tool displays "Programming has been completed successfully."