Pinpoint Test Q : The IPMB (Image Processing Module B) Does Not Respond To The Diagnostic Scan Tool
WARNING: This page is about a different car, the 2019 Ford Edge. However, it is still accessible from the selected car via links, so may be relevant.
- Refer to OEM WIRING DIAGRAMS FOR MODULE COMMUNICATIONS NETWORK - CELL 14
for schematic and connector information. Refer to OEM WIRING DIAGRAMS FOR PARKING AID - CELL 145
for schematic and connector information.
Normal Operation and Fault Conditions
The IPMB communicates on the HS-CAN2.
Possible Sources
- Fuse
- Wiring, terminals and connector
- IPMB
Visual Inspection and Pre-checks
- Verify BJB fuse 23 (15A) is OK.
- Q1 CHECK THE IPMB (IMAGE PROCESSING MODULE B) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: IPMB C2512A.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C2512A-1 Ground
Is the voltage greater than 11 volts?
Yes GO to Q2 No VERIFY BJB fuse 23 (15A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams service information to identify the possible causes of the circuit short. - Q2 CHECK THE IPMB (IMAGE PROCESSING MODULE B) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C2512A-11 Ground
Is the resistance less than 3 ohms?
Yes GO to Q3 No REPAIR the circuit. - Q3 CHECK THE HS-CAN2 (HIGH-SPEED CONTROLLER AREA NETWORK 2) CIRCUITS BETWEEN THE IPMB (IMAGE PROCESSING MODULE B) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN
- Disconnect IPMB C2512B.
- Disconnect GWM C2431.
Are the resistances less than 3 ohms?
Yes CONNECT the GWM. GO to Q4 No REPAIR the circuit in question. - Q4 CHECK FOR CORRECT IPMB (IMAGE PROCESSING MODULE B) OPERATION
- Ignition OFF.
- Disconnect and inspect all the IPMB connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPMB connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPMB. REFER to: Image Processing Module B (IPMB) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.