Home >> Ford >> 2019 >> Transit-150 Base, 3.2L Eng VIN V >> Repair and Diagnosis >> Accessories & Equipment >> Communication Devices >> Module Configuration >> Description And Operation >> Module Configuration - System Operation And Component Description >> Module Configuration and Parameter Chart >> Body Control Module (BCM) and Instrument Panel Cluster (IPC) Car Configuration
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Body Control Module (BCM) and Instrument Panel Cluster (IPC) Car Configuration

NOTE: The BCM and IPC have a unique procedure to set Car Configuration Parameters. Configuration changes made will affect several modules. If the car configuration is changed in the BCM or IPC, an adaptive learning of the car configuration may be required in some modules (such as ABS module or RCM), depending on the changed parameter.
NOTE: On the scan tool, first select Module Programming > Programmable Parameters > Car Configuration Parameter(s) > Vehicle Configuration > Retrieve the Vehicle Configuration Data. Next select Module Programming > Programmable Parameters > Car Configuration Parameter(s) > Vehicle Configuration > Modify and Reinstate Vehicle Configuration Data. Change parameters as needed.
Module Name Programmable Module Installation (PMI) Available Reprogram/Flash Capable Requires Adaptive Learning or Calibration Available Car Configuration Parameters
BCM Yes (through Car Configuration Parameters.) Yes No
NOTE: Do not change car configuration parameters except those listed below.
Trailer tow attachmentTrailer moduleTrailer module 7-position socketTail lamps level 1: Standard rear combination lampTail lamps level 2: LED rear combination lampLED rear tail lampsSeparate stop and turn tail lamps - bulbAutomatic locking
NOTE: For diesel engines, set the speed limitation using car configuration parameters only (per the steps in the note above). For gas engines, after the car configuration parameters are selected (per the steps in the note above), set the same speed limit value a second time by selecting Module Programming>Programmable Parameters>Speed Items.
Speed limitation105 kph (65 mph)113 kph (70 mph)121 kph (75 (mph)124 kph (77 mph)Manual regeneration initiation (diesel)Manual regeneration with active regeneration inhibited (diesel)
IPC Yes Yes No