Pinpoint Test O : The IPMA (Image Processing Module A) Does Not Respond To The Diagnostic Scan Tool
WARNING: This page is about a different car, the 2020 Lincoln Corsair. However, it is still accessible from the selected car via links, so may be relevant.
- Refer to MODULE COMMUNICATIONS NETWORK
for schematic and connector information. Refer to CRUISE CONTROL
for schematic and connector information.
Normal Operation and Fault Conditions
The IPMA communicates on the HS-CAN2.
Possible Sources
- Fuse
- Wiring, terminals and connector
- IPMA
Visual Inspection and Pre-checks
- Verify BCM fuse 9 (5A) is OK.
- O1 CHECK THE IPMA (IMAGE PROCESSING MODULE A) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: IPMA C9039.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C9039-4 Ground
Is the voltage greater than 11 volts?
Yes GO to O2 No VERIFY BCM fuse 9 (5A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the OEM ELECTRICAL WIRING DIAGRAM INTRODUCTION to identify the possible causes of the circuit short. - O2 CHECK THE IPMA (IMAGE PROCESSING MODULE A) GROUND CIRCUIT FOR AN OPEN
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead C9039-5 Ground
Is the resistance less than 3 ohms?
Yes GO to O3 No REPAIR the circuit. - O3 CHECK THE HS-CAN2 (HIGH-SPEED CONTROLLER AREA NETWORK 2) CIRCUITS BETWEEN THE IPMA (IMAGE PROCESSING MODULE A) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN
- Disconnect GWM C2431.
Are the resistances less than 3 ohms?
Yes GO to O4 No REPAIR the circuit in question. - O4 CHECK FOR CORRECT IPMA (IMAGE PROCESSING MODULE A) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPMA connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPMA connector. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, General Service Bulletin (GSB), SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPMA. REFER to: Image Processing Module A (IPMA) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.