| 2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost without climate controlled seats or Alternating Current (AC) power outlet socket - 200 amp |
| Generator amps at 80.6°F (27°C) |
130 amps at 675 rpm (min) to 200 amps at 2, 250 rpm (max) |
| Generator pulley ratio |
2.67:1 |
| Generator pulley replaceable |
Yes |
| Generator pulley type |
Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type |
Electronic internal with generator |
| 2.7L EcoBoost, 3.3L Duratec and 3.5L EcoBoost with climate controlled seats or Alternating Current (AC) power outlet socket - 240 amp |
| Generator amps at 80.6°F (27°C) |
130 amps at 675 rpm (min) to 240 amps at 2, 250 rpm (max) |
| Generator pulley ratio |
2.67:1 |
| Generator pulley replaceable |
Yes |
| Generator pulley type |
Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type |
Electronic internal with generator |
| 3.0L Power Stroke Diesel - 250 amp |
| Generator amps at 80.6°F (27°C) |
140 amps at 700 rpm (min) to 250 amps at 2, 300 rpm (max) |
| Generator pulley ratio |
2.67:1 |
| Generator pulley replaceable |
Yes |
| Generator pulley type |
Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type |
Electronic internal with generator |
| 5.0L Ti-VCT without climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 200 amp |
| Generator amps at 80.6°F (27°C) |
130 amps at 640 rpm (min) to 200 amps at 2, 135 rpm (max) |
| Generator pulley ratio |
2.81:1 |
| Generator pulley replaceable |
No |
| Generator pulley type |
Solid |
| Voltage regulator type |
Electronic internal with generator |
| 5.0L Ti-VCT with climate controlled seats, snowplow or Alternating Current (AC) power outlet socket - 240 amp |
| Generator amps at 80.6°F (27°C) |
130 amps at 675 rpm (min) to 240 amps at 2, 250 rpm (max) |
| Generator pulley ratio |
2.81:1 |
| Generator pulley replaceable |
No |
| Generator pulley type |
Solid |
| Voltage regulator type |
Electronic internal with generator |