| B00D5:01 |
Restraint System Passenger Disable Indicator: General Electrical Failure |
REFER to the appropriate service information in SUPPLEMENTAL RESTRAINT SYSTEM (1 OF 2)
/
SUPPLEMENTAL RESTRAINT SYSTEM (2 OF 2)
. |
| B105A:12 |
Cabin Temperature Sensor Fan: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B105A:14 |
Cabin Temperature Sensor Fan: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1081:07 |
Left Temperature Damper Motor: Mechanical Failure |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1081:11 |
Left Temperature Damper Motor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1081:12 |
Left Temperature Damper Motor: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1081:13 |
Left Temperature Damper Motor: Circuit Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1082:07 |
Right Temperature Damper Motor: Mechanical Failure |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1082:11 |
Right Temperature Damper Motor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1082:12 |
Right Temperature Damper Motor: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1082:13 |
Right Temperature Damper Motor: Circuit Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1083:07 |
Recirculation Damper Motor: Mechanical Failure |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1083:11 |
Recirculation Damper Motor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1083:12 |
Recirculation Damper Motor: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1083:13 |
Recirculation Damper Motor: Circuit Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1086:07 |
Air Distribution Damper Motor: Mechanical Failure |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1086:11 |
Air Distribution Damper Motor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1086:12 |
Air Distribution Damper Motor: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1086:13 |
Air Distribution Damper Motor: Circuit Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10AF:11 |
Blower Fan Relay: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10AF:15 |
Blower Fan Relay: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B3:11 |
Right Panel Air Discharge Temperature: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B3:15 |
Right Panel Air Discharge Temperature: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B4:11 |
Right Floor Air Discharge Temperature: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B4:15 |
Right Floor Air Discharge Temperature: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B5:11 |
Left Panel Air Discharge Temperature: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B5:15 |
Left Panel Air Discharge Temperature: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B6:11 |
Left Floor Air Discharge Temperature: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B6:15 |
Left Floor Air Discharge Temperature: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B8:63 |
Push Buttons: Circuit / Component Protection Time-Out |
GO to Pinpoint Test AX |
| B10B9:12 |
Blower Control: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B10B9:14 |
Blower Control: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B11E5:14 |
Left HVAC Damper Position Sensor: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B11E6:14 |
Right HVAC Damper Position Sensor: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B11E7:14 |
Air Distribution Damper Position Sensor: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B11F0:14 |
Air Intake Damper Position Sensor: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1202:01 |
Restraint System Passenger Enable Indicator: General Electrical Failure |
REFER to SUPPLEMENTAL RESTRAINT SYSTEM (1 OF 2)
/
SUPPLEMENTAL RESTRAINT SYSTEM (2 OF 2)
. |
| B1A61:11 |
Cabin Temperature Sensor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A61:15 |
Cabin Temperature Sensor: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A63:11 |
Right Solar Sensor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A63:15 |
Right Solar Sensor: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A64:11 |
Left Solar Sensor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A64:15 |
Left Solar Sensor: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A69:12 |
Humidity Sensor: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1A69:14 |
Humidity Sensor: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1B71:11 |
Evaporator Temperature Sensor: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1B71:15 |
Evaporator Temperature Sensor: Circuit Short To Battery or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1C83:12 |
Rear Defog Relay: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| B1C83:14 |
Rear Defog Relay: Circuit Short To Ground or Open |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| C1B14:11 |
Sensor Supply Voltage A: Circuit Short To Ground |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| C1B14:12 |
Sensor Supply Voltage A: Circuit Short To Battery |
REFER to: CLIMATE CONTROL SYSTEM - GENERAL INFORMATION (1 OF 2)
. |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test AF |
| U0151:00 |
Lost Communication With Restraints Control Module: No Sub Type Information |
GO to Pinpoint Test AH |
| U0155:00 |
Lost Communication With Instrument Panel Cluster (IPC) Control Module: No Sub Type Information |
GO to Pinpoint Test AI |
| U0253:00 |
Lost Communication With Accessory Protocol Interface Module: No Sub Type Information |
GO to Pinpoint Test AQ |
| U0401:00 |
Invalid Data Received from ECM/PCM A: No Sub Type Information |
GO to Pinpoint Test AV |
| U0401:82 |
Invalid Data Received from ECM/PCM A: Alive / Sequence Counter Incorrect / Not Updated |
GO to Pinpoint Test AV |
| U0422:68 |
Invalid Data Received From Body Control Module: Event Information |
GO to Pinpoint Test AV |
| U0422:81 |
Invalid Data Received From Body Control Module: Invalid Serial Data Received |
GO to Pinpoint Test AV |
| U0452:82 |
Invalid Data Received From Restraints Control Module: Alive / Sequence Counter Incorrect / Not Updated |
GO to Pinpoint Test AV |
| U1000:00 |
Solid State Driver Protection Active -Driver Disabled: No Sub Type Information |
GO to Pinpoint Test AZ |
| U2024:51 |
Control Module Cal-Config Data: Not Programmed |
GO to Pinpoint Test AW |
| U2100:00 |
Initial Configuration Not Complete: No Sub Type Information |
GO to Pinpoint Test AW |
| U3000:41 |
Control Module: General Checksum Failure |
GO to Pinpoint Test AX |
| U3000:49 |
Control Module: Internal Electronic Failure |
GO to Pinpoint Test AX |
| U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test AS |
| U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test AT |