LP1014 - WASTEGATE Control Pressure Sensor Circuit Intermittent/Erratic
DTC DESCRIPTION P1014 - WASTEGATE CONTROL PRESSURE SENSOR CIRCUIT INTERMITTENT/ERRATIC
| Description: | This DTC sets when the wastegate vacuum sensor reading is less than or greater than the minimum or maximum calibrated thresholds and the fault counter has exceeded the calibrated count threshold indicating an intermittent open or short circuit. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | The typical minimum and maximum threshold is 0.2 V and 4.93 V and the count threshold is 25. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test HN. | ||