P1012 - WASTEGATE Control Pressure Sensor Circuit Low
DTC DESCRIPTION P1012 - WASTEGATE CONTROL PRESSURE SENSOR CIRCUIT LOW
| Description: | This DTC sets when the wastegate vacuum sensor reading is less than a calibrated threshold and the fault timer has exceeded the calibrated time threshold indicating a short to SIGRTN or ground. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | The typical minimum threshold is 0.2V and time threshold is 5 seconds. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test HN. | ||