P1011 - WASTEGATE Control Pressure Sensor Circuit Range/Performance
DTC DESCRIPTION P1011 - WASTEGATE CONTROL PRESSURE SENSOR CIRCUIT RANGE/PERFORMANCE
| Description: | This DTC sets when the wastegate vacuum sensor reading has exceeded the atmospheric pressure by greater than a calibrated threshold and the fault timer has exceeded the calibrated time threshold. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | The typical maximum threshold is 10.16 kPa (1.47 psi) and time threshold is 5 seconds. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test HN. | ||