Pinpoint Test Ag: Reduced Outlet Airflow
- Possible Sources
- Plugged cabin air filter
- Improper A/C system refrigerant charge
- Blower motor
- AG1 CHECK THE CABIN AIR FILTER
- Ignition OFF.
- Inspect the cabin air filter for possibly plugged or wet. REFER to: Cabin Air Filter
Is the cabin air filter plugged?
Yes REPLACE or REPAIR as needed. No GO to AG2 - AG2 CHECK THE BLOWER MOTOR OPERATION
- Ignition ON.
- Using the HVAC controls, select panel mode, set temperature to mid range.
- Operate the blower motor through all speeds.
- Turn off the blower motor.
Does the blower motor operate properly?
Yes GO to AG3 No DIAGNOSE the blower motor concern. GO to Pinpoint Test N - AG3 CHECK THE AIR CONDITIONING (A/C) SYSTEM FOR PROPER CHARGENOTE: Proper Air Conditioning (A/C) system diagnosis on a vehicle's compressor is dependent on correct refrigerant system charge and tested in ambient temperatures above 21. 1 deg. C (70 deg. F).
- Carry out the Refrigerant System Tests. REFER to: Refrigerant System Tests - 2. 3L EcoBoost (199kW/270PS) REFER to: Refrigerant System Tests - 2. 7L EcoBoost (238kW/324PS)
Did the system pass the refrigerant system tests?
Yes The system is operating correctly at this time. No REPAIR the concern found in the refrigerant system tests chart.