Home >> Ford >> 2021 >> Bronco Base, 2D Utility, 2.3L Eng VIN H, Part Time T/Case Control, Automatic Trans >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System - General Information (2 Of 2) >> General Procedures >> Air Conditioning (A/C) System Leak Test Using Forming Gas
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Air Conditioning (A/C) System Leak Test Using Forming Gas

For information on Ford Color Coded Illustrations refer to OEM COLOR CODING

Special Tool(s) / General Equipment 

Forming Gas Pressure Gauge and Leak Detector

Materials 

Name Specification
Forming Gas -

Leak detection 

All vehicles 

  1. NOTE: Use a Rotunda-approved Tracer Gas A/C System Dealership Leak Detection Service Kit that meets SAE J2790.

    Recover the refrigerant. Refer to the appropriate Recovery procedure in the appropriate Climate Control System service information.

    Hybrid\Electric vehicles 

  2. Electric or Hybrid vehicle with a battery chiller. It may be necessary to activate the battery chiller(s) to open the solenoid(s) to allow vacuum and gas to pass through to chiller for leak testing. Refer to appropriate service information refrigerant reclaim and charging to see if solenoid(s) activation is necessary. Follow the appropriate service information procedure to perform activation if needed.

    All vehicles 

  3. Perform the vacuum leak test in accordance with the service unit manufacturer instructions.
  4. Assemble tracer gas leak detection kit per manufacturer instructions.
  5. Connect the forming gas pressure gauge and leak detector service hose to the high-pressure port of the air conditioning system in accordance with the manufacturer instructions. Use the General Equipment: Forming Gas Pressure Gauge and Leak Detector

    Material: Forming Gas

    GFD627191Courtesy of FORD MOTOR COMPANY
  6. NOTE: Make sure that the pressure reducer (2) is closed.

    1. Open the bottle valve.
    2. Slowly turn the pressure reducer until a pressure of 4. 1 bar (60 psi) is reached. Maintain open for 30 seconds to allow tracer gas to fill system.
    3. Close the bottle valve.
    4. For the correct Model 740KIT - Tracer Gas A/C System Dealership Leak Detection Service Kit. Refer to: Climate Control Tools and Equipment 

    GFD627192Courtesy of FORD MOTOR COMPANY
  7. Leak test the refrigerant system. Follow the instructions included with the Leak Detector for handling and operation techniques.

  8. NOTE: Trace gas is lighter than air, and tends to move up from the source of the leak. It is possible that a leak may not be detected if the leak detector tip is held below the leaking fitting, line or component. Always be sure to thoroughly leak test below, above and around the fitting, line or component.

    Disconnect the forming gas pressure gauge and leak detector from the air conditioning system in accordance with the manufacturer instructions.

  9. NOTE: Do not ever recover the tracer gas into the A/C recovery/charging machine.
    NOTE: Discharge the H2/N2 tracer gas into the atmosphere after the system leak/s are located.

    Charge the system with the appropriate refrigerant only after the leak/s are repaired and retested with the H2/N2 tracer gas and the model D740 leak detector. Refer to the appropriate Recharging procedure in the appropriate Climate Control System service information.