Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AC_REQ PID NO NO NO NO YES/NO
APP APP Sensor 0 0 3.50 18 %
APP1 APP Sensor 0.76 0.76 0.88 1.33 VOLTS
APP1 (APP_D) APP Sensor 14.90 14.90 17.64 26.66 %
APP2 APP Sensor 0.38 0.38 0.44 0.67 VOLTS
APP2 (APP_E) APP Sensor 7.45 7.45 8.62 13.33 %
APP_MAXDIFF PID 0 0 0 0 DEG
APP_MODE PID NO PEDAL NO PEDAL PART PEDAL PART PEDAL NO PEDAL/PART PEDAL
B+ PID 12.36 13.49 13.62 13.54 VOLTS
BARO PID 93 (13.49) 150.62 93 (13.49) 150.62 93 (13.49) 150.62 104 (15.08) 160.42 kPa (PSI)/Hz
BOO1 BPP Switch OFF OFF OFF OFF ON/OFF
BOO2 BPP Switch OFF OFF OFF OFF ON/OFF
BRKOVRD_POSS PID 1 1 2 2 NUMERIC VALUE
BRKOVR_ACTION PID 0 0 0 0 NUMERIC VALUE
CHT CHT Sensor 0.60/85 (185) 3.65/87 (188.6) 0.56/87 (188.6) 3.56/89 (192.2) VOLTS/DEG C (DEG F)
CLRDIST PID 0 0 0 2 (1.24) KM (MILES)
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 0.5 (0.31) 0.5 (0.31) 0.5 (0.31) 1.99 (1.24) KM (MILES)
DTCCNT PID 0 0 0 0 Numeric Value
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
EQ_RAT11 PID 0:1 13.74:1 15.22:1 14.33:1 RATIO
EQ_RAT21 PID 0:1 13.73:1 14.78:1 14.43:1 RATIO
ETC_ACT PID 8.22 4.62 3.67 9.30 DEG
ETC_TRIM PID -0.08 -0.08 0.09 0.09 DEG
FANSS FS Sensor 0 500 425 500 RPM
FF_INF PID 9.80 9.80 9.80 9.80 %
FF_LRND PID NO NO YES YES YES/NO
FLI Fuel Level Sensor 69.41 (H) 70.58 (H) 74.11 (H) 67.45 (H) %
FPM PID 60.60 60.99 60.99 61.02 %
FTP FTP Sensor 2.63/21 (0) 2.63/21 (0) 2.57/-82 (-0.01) 2.37/-443 (-0.06) VOLTS/Pa (PSI)
FTP_H2O FTP Sensor 0.07 0.07 -0.37 -1.79 NUMERIC VALUE
HTRCM11 HO2S11 Sensor 0 0 0 0 mA
HTRCM12 HO2S12 Sensor 0 0 0 0 mA
HTRCM21 HO2S21 Sensor 0 0 0 0 mA
HTRCM22 HO2S22 Sensor 0 0 0 0 mA
IAT IAT Sensor 1.76/41 (105.8) 1.82/39 (102.2) 2.38/26 (78.8) 2.41/25 (77) VOLTS/DEG C (DEG F)
INJPWR_M PID 12.46 13.63 13.70 13.80 VOLTS
KEYST Ignition Switch ON ON ON ON ON/OFF
KNOCK_1 KS1 Sensor 0 73 103 136 COUNT
KNOCK_2 KS2 Sensor 0 71 167 161 COUNT
LOAD PID 0.00 (I) 25.88 52.94 37.25 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 2.57 6.51 19.07 22.88 g/s
MAF_HZ MAF Sensor 680.25 2.20 3.31 3.59 kHz
MIL_DIS PID 0 0 0 0 KM (MILES)
MISFIRE PID NO NO NO NO YES/NO
MP_LRN PID YES YES YES YES YES/NO
NUM_MISFIRE PID 0 0 2 2 COUNT
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5 0.06 0.09 0.09 VOLTS
O2S11_READY HO2S11 Sensor NO YES YES YES YES/NO
O2S11_TR HO2S11 Sensor 0 0 0 0 Kohm
O2S12 HO2S12 Sensor (I) switching (D) switching (D) switching (D) VOLTS
O2S21 HO2S21 Sensor (I) switching (C) switching (C) switching (C) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5 0.06 0.09 0.09 VOLTS
O2S21_READY HO2S21 Sensor NO YES YES YES YES/NO
O2S21_TR HO2S21 Sensor 0 0 0 0 Kohm
O2S22 HO2S22 Sensor (I) switching (D) switching (D) switching (D) VOLTS
OSS_SRC OSS Sensor 0 0 1333 2597.25 RPM
PTOIR_V PID 0 0 0 0 VOLTS
RO2FT1 PID 0 -0.39 -1.07 -2.16 %
RO2FT2 PID 0 -0.36 -1.07 -2.19 %
RPM CKP Sensor 0 628.25 1212.50 1760.50 RPM
SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.17/16.47 4.35/12.94 4.15/18.43 3.62/27.45 VOLTS/%
TP1_LRN_TRIM ETBTPS 8.87 8.87 8.87 8.87 DEG
TP2 ETBTPS 0.82/16.47 0.65/12.54 0.73/18.43 1.15/27.45 VOLTS/%
TP2_LRN_TRIM ETBTPS 8.75 8.75 8.75 8.75 DEG
TP_MAXDIFF PID 0 0 0 -0.06 %
TQ_CNTRL PID NONE REQUESTED IDLE SPEED CONTROL NONE REQUESTED TORQUE BASED DECEL STATUS
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
VSS PID 0 0 48 KM/H (30 MPH) 89 KM/H (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
CYL 1-8_ACCL PID (I) -1 TO +1 -1 TO +1 -1 TO +1 NUMERIC VALUE
ETC [TAC_PCT] PID 9.02 5.09 3.92 10.98 %
EVAP020C PID NO NO NO NO YES/NO
EVAPCP EVAPCP Valve 0 0 37.98 82.85 %
EVAPCV CANV Valve 0/OFF 0/OFF 0/OFF 0/OFF %/ON-OFF
EVAPSOAK PID YES YES YES YES YES/NO
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FANDC PID 0 0 0 0 %
FAN_DSD PID 0 199.99 199.99 199.99 %
FP Fuel Pump Control Module 75/OFF 34.40/ON 33.89/ON 33.96/ON %/ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/CLOSED LOOP
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
INJ1-8_OFF Injector 1-8 -- -- -- -- --/DISABLE
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 20.78 60 36.86 27.84 %
O2S21_HTR HO2S21 Sensor 20.78 61.17 37.25 30.19 %
O2_DS_DISBL PID YES NO NO NO YES/NO
PATSENABL PID ENABLED ENABLED ENABLED ENABLED ENABLED/DISABLED
PTOIL PTO Lamp OFF OFF OFF OFF ON/OFF
SPARKADV PID 29.50 19.75 38.50 46.75 DEG
VCTADV PID 0 0 34.56 34.93 DEG
VCTADV2 PID 0 -0.12 34.56 35 DEG
VCTADVERR PID 0 0 -0.06 0.18 DEG
VCTADVERR2 PID 0 0.12 0 0.12 DEG
VCTDC VCT1 Solenoid 0 0 53.19 53.02 %
VCTDC2 VCT2 Solenoid 0 0 52.27 51.84 %
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID VBAT VBAT VBAT VBAT VOLTS
VREF PID 5 5 5 5 VOLTS