Dual Generators
Vehicles with the 2.7L Ecoboost /3.5L Ecoboost engine may have dual generators. In dual generator systems, the PCM keeps the secondary generator in a standby state where it does not generate current unless the primary generator is generating full power and more current is needed to support the vehicle loads. The PCM monitors the output of the primary generator and adjusts the control setpoint of the secondary generator to cause it to provide additional current when needed.