LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2022 >> F-150 Police Responder >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Electronic Engine Controls - 3.5L ECOBOOST (BM) >> Specifications >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

NOTE: Footnotes are referenced throughout the Typical Diagnostic Reference Value Charts. A letter in parentheses next to a value indicates supplemental information is available.

An attempt is made to provide as much information as possible. Some vehicles may not display all input and output signals.

The Typical Diagnostic Reference Value Charts do not display fault parameter identifications (PIDs). These are PIDs which indicate a hard fault with the circuit. They display a value of FAULT or NO FAULT and are PIDs ending with the letter F.

Reference values may vary 20% depending on operating conditions, altitude, and other factors. The RPM values are axle and tire dependent.

Values are taken at an altitude of approximately 189 meters (620 ft) above sea level with the engine at normal operating temperature and accessories off.

For detailed transmission diagnostics, refer to the Service Information. Transmission signals may be referred to in either alpha or numeric form. For example, 1=A, 2=B, 3=C.

PID Units Measured/PID Component/PID Only Measured/PID Values
KOEO Hot Idle 48KM/H (30 MPH) 89 KM/H (55 MPH)
PCM AAT (°C) DEG C (°F) AAT Sensor 15 (59) 15 (59) 15 (59) 14 (57.2)
PCM AAT_V (V) VOLTS AAT Sensor 3.22 3.23 3.24 3.29
PCM APP (%) % APP Sensor 0 0 13 15
PCM APP1 (V) VOLTS APP Sensor 0.78 0.78 1.19 1.25
PCM APP1_[APP_D] (%) % APP Sensor 16 15 24 25
PCM APP2 (V) VOLTS APP Sensor 0.41 0.41 0.62 0.64
PCM APP2_[APP_E] (%) % APP Sensor 8 8 12 13
PCM APP_MAXDIFF (Deg) DEG PID 0.00 0.00 -0.06 -0.06
PCM BARO (kPa) kPa (PSI) PID 99.00 (14.36) 99.00 (14.36) 99.00 (14.36) 99.00 (14.36)
PCM BARO_V (V) VOLTS PID 3.86 3.86 3.86 3.85
PCM BATT_V_INF (V) VOLTS PID 12.94 14.50 14.50 14.50
PCM BRKOVRD_POSS (Undefined / Not Used) NUMERIC VALUE PID 46 46 46 46
PCM BRKOVR_ACTION (Undefined / Not Used) NUMERIC VALUE PID 0 0 0 0
PCM CAC_T (°C) DEG C (°F) CACT Sensor 43 (109.4) 41 (105.8) 38 (100.4) 36 (96.8)
PCM CAM_SYNC YES/NO PID No (False) No (False) No (False) No (False)
PCM CATTEMP11 (°C) DEG C (°F) CAT11 Sensor 428 (802.4) 421 (789.8) 502 (935.6) 722 (1, 331.6)
PCM CATTEMP21 (°C) DEG C (°F) CAT21 Sensor 428 (802.4) 421 (789.8) 502 (935.6) 722 (1, 331.6)
PCM CHT (°C) DEG C (°F) CHT Sensor 95(203) 95 (203) 97 (206.6) 102 (215.6)
PCM CHT_V (V) VOLTS CHT Sensor 3.54 3.54 3.37 3.34
PCM CLRDIST (km) KM (MILES) PID 3.0 (1.86) 3.0 (1.86) 3.0 (1.86) 4.0 (2.49)
CRNKCAS_PRS kPa (PSI) Crankcase Pressure Sensor -0.01 (-0.00) 0.03 (0.00) 0.02 (0.00) -0.06 (-0.01)
CRNKCAS_P_V VOLTS Crankcase Pressure Sensor 3.36 3.34 3.34 3.32
PCM DECHOKE YES/NO PID Yes (True) No (False) No (False) No (False)
PCM DIST_AEIS (km) KM (MILES) PID 0.0 (0.0) 0.0 (0.0) 0.0 (0.0) 0.0 (0.0)
PCM DIST_BRKOVRD (km) KM (MILES) PID 57.5 (35.73) 57.5 (35.73) 57.5 (35.73) 59.0 (36.66)
PCM DPFE_PRES (kPa) kPa (PSI) Differential Pressure Feedback EGR Sensor 0.22 (0.03) 0.22 (0.03) 1.68 (0.01) 6.20 (0.90)
PCM DPFE_V (V) VOLTS Differential Pressure Feedback EGR Sensor 1.51 1.51 1.57 1.79
PCM DTCCNT (Undefined / Not Used) NUMERIC VALUE PID 0 0 0 0
PCM DTCCNT_OBD (Undefined / Not Used) NUMERIC VALUE PID 0 0 0 0
PCM EBP (kPa) kPa (PSI) EBP Sensor 100.32 (14.55) 112.54 (16.32) 101.24 (14.68) 107.89 (15.65)
PCM EBP_V (V) VOLTS EBP Sensor 0.99 0.95 0.94 0.96
PCM ECT (°C) DEG C (°F) ECT Sensor 87 (188.6) 86 (186.8) 87(188.6) 89 (192.2)
PCM EGRT_B (°C) DEG C (°F) EGRT12 Sensor 16 (60.8) -16 (3.2) -10 (14) -11 (12.2)
PCM EGRT_B_V (V) VOLTS EGRT12 Sensor 0.64 0.63 3.13 3.16
PCM EGRVP (V) VOLTS EGR Valve 0.52 0.52 0.78 1.32
PCM EGRVPDES (%) % PID 0 0 7 19
PCM EGR_A_ACT (%) % EGR Valve 0 0 6 19
PCM EGR_A_CMD (%) % PID 0 0 7 19
PCM EQ_RAT11 (Undefined / Not Used) RATIO PID 0.00 1.01 1.04 0.98
PCM EQ_RAT21 (Undefined / Not Used) RATIO PID 0.00 1.00 1.01 0.98
PCM ETC_ACT (Deg) DEG PID 0.00 4.66 13.84 14.96
PCM ETC_TRIM (Deg) DEG PID 0.03 (E) 0.03 (E) 0.03 (E) 0.03 (E)
PCM ETC_[TAC_PCT] (%) % PID 9 5 17 18
PCM EVAP020C YES/NO PID No (False) No (False) No (False) No (False)
PCM EVAPCP (%) % EVAPCP Valve 0 5 99 77
PCM EVAPCV (%) % CANV Valve 0 0 0 0
PCM EVAPPCT (%) % PID 0 5 98 77
PCM EVAPSOAK YES/NO PID Yes (True) Yes (True) Yes (True) Yes (True)
PCM EVAPSTA STATUS PID Not Running Not Running Not Running Not Running
PCM EVBV (% Duty Cycle) % EVAP Vapor Blocking Valve 0 0 100 100
PCM FAN_DSD (%) % PID 0 0 0 0
PCM FLI (%) % Fuel Level Sensor 40 (B) 40 (B) 33 (B) 43 (B)
PCM FLP (kPa) kPa (PSI) Fuel Pressure Sensor 519 (75.27) 487 (70.63) 484 (70.20) 497 (72.08)
PCM FLP_DSD (kPa) kPa (PSI) Fuel Pressure Sensor 486 (70.49) 483 (70.05) 480 (69.62) 474 (68.75)
PCM FLP_V (V) VOLTS Fuel Pressure Sensor 2.57 2.45 2.43 2.49
PCM FP (%) % Fuel Pump Control Module 75 19 19 19
PCM FPM (%) % PID 41 40 40 41
PCM FRP (kPa) kPa (PSI) FRP Sensor 29, 030 (4, 210.45) 25, 060 (3, 634.65) 3, 700 (536.64) 13, 140 (1, 905.80)
PCM FRP_DSD (kPa) kPa (PSI) PID 440 (63.82) 3, 100 (449.62) 3, 730 (540.99) 12, 560 (1, 821.67)
PCM FRP_V (V) VOLTS FRP Sensor 3.82 3.36 0.92 2.00
PCM FTP_V (V) VOLTS FTP Sensor 2.65 2.64 2.19 2.56
PCM FUELSYS_A_PCT_B1 (%) % PID 0 0 36 71
PCM FUELSYS_A_PCT_B2 (%) % PID 0 0 36 71
PCM FUELSYS_B_PCT_B1 (%) % PID 0 100 64 29
PCM FUELSYS_B_PCT_B2 (%) % PID 0 100 64 29
PCM FUELSYS_CL YES/NO PID No Yes Yes Yes
PCM FUELSYS_OL YES/NO PID No No No No
PCM F_VCV_CMD (%) % Fuel Injection Pump 0 0 1 11
PCM HTR11 ON/OFF HO2S11 Sensor Off On On On
PCM HTR12 ON/OFF HO2S12 Sensor Off On On On
PCM HTR21 ON/OFF HO2S21 Sensor Off On On On
PCM HTR22 ON/OFF HO2S22 Sensor Off On On On
PCM HTRCM11 (Amp) mA HO2S11 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM12 (Amp) mA HO2S12 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM21 (Amp) mA HO2S21 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM22 (Amp) mA HO2S22 Sensor 0.00 0.00 0.00 0.00
PCM IAT (°C) DEG C (°F) IAT Sensor 53 (127.4) 52 (125.6) 45(113) 35 (95)
PCM IAT11 (°C) DEG C (°F) IAT Sensor 53 (127.4) 52 (125.6) 45 (113) 35 (95)
PCM IAT12 (°C) DEG C (°F) IAT2 Sensor 53 (127.4) 52 (125.6) 50 (122) 44 (111.2)
PCM IAT1_V (V) VOLTS IAT Sensor 1.30 1.32 1.54 1.97
PCM IAT2 (°C) DEG C (°F) IAT2 Sensor 53 (127.4) 52 (125.6) 50 (122) 44 (111.2)
PCM IAT2_V (V) VOLTS IAT2 Sensor 1.28 1.32 1.40 1.58
PCM INJECTOR_OFF -----/DISABLE Injector 16 ----- ----- ----- -----
PCM INJPWR_M (V) VOLTS PID 12.91 14.43 14.38 14.43
PCM KNK_CNTR_CYL1 (Undefined / Not Used) COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL2 (Undefined / Not Used) COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL3 (Undefined / Not Used) COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL4 (Undefined / Not Used) COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL5 (Undefined / Not Used) COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL6 (Undefined / Not Used) COUNT PID 0 0 0 0
PCM KNOCK_1 (Undefined / Not Used) COUNT KS11 Sensor 999.00 74.00 60.00 58.00
PCM KNOCK_2 (Undefined / Not Used) COUNT KS12 Sensor 999.00 62.00 68.00 76.00
PCM KNOCK_3 (Undefined / Not Used) COUNT KS21 Sensor 999.00 84.00 64.00 62.00
PCM KNOCK_4 (Undefined / Not Used) COUNT KS22 Sensor 999.00 60.00 47.00 64.00
PCM LOAD (%) % PID 0 (A) 47 32 40
PCM LOAD_ABSL (%) % PID 0 (A) 29 24 36
PCM LONGFT1 (%) % PID -3.91 (A) -20 TO +20 -20 TO +20 -20 TO +20
PCM LONGFT2 (%) % PID -0.78 (A) -20 TO +20 -20 TO +20 -20 TO +20
PCM MAP (kPa) kPa (PSI) MAP Sensor 97.0 (14.07) 54.0 (7.83) 52.0 (7.54) 70.0 (10.15)
PCM MAP_V (V) VOLTS MAP Sensor 1.49 0.84 0.81 1.07
PCM MIL_DIS (km) KM (MILES) PID 0 (0) 0 (0) 0 (0) 0 (0)
PCM MIL_OBD ON/OFF PID Off Off Off Off
PCM MISFIRE TRUE/FALSE PID False False False False
PCM NUM_MISFIRE (Undefined / Not Used) COUNT PID 0 0 0 0
PCM O2S11_CUR (mA) mA HO2S11 Sensor (A) switching (C) switching (C) switching (C)
PCM O2S11_HTR (%) % HO2S11 Sensor 20 73 25 24
PCM O2S11_IMPED (V) VOLTS HO2S11 Sensor 5.00 1.01 1.05 1.04
PCM O2S11_TR (Ohm) Ohms HO2S11 Sensor 0.00 101, 000.00 101, 000.00 101, 000.00
PCM O2S12 (V) VOLTS HO2S12 Sensor (A) switching (D) switching (D) switching (D)
PCM O2S21_HTR (%) % HO2S21 Sensor 20 73 25 24
PCM O2S21_IMPED (V) VOLTS HO2S21 Sensor 5.00 1.05 1.04 1.05
PCM O2S21_READY TRUE/FALSE HO2S21 Sensor False True True True
PCM O2S21_TR (Ohm) Ohms HO2S21 Sensor 0.00 127, 400.00 127, 400.00 127, 400.00
PCM O2S22 (V) VOLTS HO2S22 Sensor (A) switching (D) switching (D) switching (D)
PCM OCTADJ_R_LRND (Undefined / Not Used) % PID -0.21 -0.21 -0.21 -0.21
PCM PATSENABL ENABLED / DISABLED PID Enabled Enabled Enabled Enabled
PCM RO2FT1 (%) % PID 0.00 0.00 0.02 0.03
PCM RO2FT2 (%) % PID 0.00 0.00 0.02 0.03
PCM RPM (Rpm) RPM CKP Sensor 0 882 1, 446 1, 312
PCM RPM_DSD (Rpm) RPM PID 899 899 550 550
PCM SHRTFT1 (%) % PID 0.00 (A) -10 TO +10 -10 TO +10 -10 TO +10
PCM SHRTFT2 (%) % PID 0.00 (A) -10 TO +10 -10 TO +10 -10 TO +10
PCM SPARKADV (Deg) DEG PID 7.00 -3.50 17.50 30.00
PCM SYNC YES/NO PID No (False) No (False) YES (True) YES (True)
PCM TCBP (kPa) kPa (PSI) TCBP Sensor 98.4 (14.27) 98.4 (14.27) 99.5 (14.43) 101.6 (14.74)
PCM TCBP_V (V) VOLTS TCBP Sensor 1.41 1.41 1.43 1.45
PCM TP1_LRN_TRIM (Deg) DEG ETBTPS 10.13 10.13 10.13 10.13
PCM TP1_PER (%) % ETBTPS 17 17 16 17
PCM TP2_LRN_TRIM (Deg) DEG ETBTPS 0.00 0.00 0.00 0.00
PCM TP_REL (%) VOLTS PID 7.1 7.1 5.5 7.5
PCM TURBO_BP1_STAT FAULT/NO FAULT TCBY Valve NO FAULT NO FAULT NO FAULT NO FAULT
PCM TURBO_BPASS (%) % TCBY Valve 0 0 0 100
PCM VCTSYS ENABLED / DISABLED PID DISABLED DISABLED ENABLED ENABLED
PCM VCT_EXH_ACT1 (Deg) DEG PID 0.00 -0.06 39.19 40.81
PCM VCT_EXH_ACT2 (Deg) DEG PID 0.00 0.06 39.63 41.13
PCM VCT_EXH_DC1 (%) % VCT12 Solenoid 0 0 40 49
PCM VCT_EXH_DC2 (%) % VCT22 Solenoid 0 0 38 48
PCM VCT_EXH_DIF1 (Deg) DEG PID 0.00 0.06 -2.56 5.38
PCM VCT_EXH_DIF2 (Deg) DEG PID 0.00 -0.06 -2.13 5.25
PCM VCT_INT_ACT1 (Deg) DEG PID 0.00 0.19 0.00 -0.13
PCM VCT_INT_ACT2 (Deg) DEG PID 0.00 0.13 -0.06 0.06
PCM VCT_INT_DC1 (%) % VCT11 Solenoid 0 0 0 0
PCM VCT_INT_DC2 (%) % VCT21 Solenoid 0 0 0 0
PCM VCT_INT_DIF1 (Deg) DEG PID 0.00 -0.31 0.06 0.13
PCM VCT_INT_DIF2 (Deg) DEG PID 0.00 -0.13 0.00 -0.06
PCM VPWR (V) VOLTS PID 13.19 14.40 14.35 14.32
PCM VREF (V) VOLTS PID 5.01 5.01 5.01 5.01
PCM VSS (Kph) km/h (MPH) PID 0 (0) 0 (0) 48 km/h (30 MPH) 89 km/h (55 MPH)
PCM WGATE_A_POS_PCT (% Open) % Turbocharger Wastegate Motor 1 32.60 99.89 89.69 99.84
PCM WGATE_A_V (V) VOLTS Wastegate Position Sensor 1 2.27 4.04 3.86 4.07
PCM WGATE_B_POS_PCT (% Open) % Turbocharger Wastegate Motor 2 32.65 99.84 90.18 99.89
PCM WGATE_B_V (V) VOLTS Wastegate Position Sensor 2 2.44 4.21 3.98 4.23