LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2023 >> Bronco Raptor >> Repair and Diagnosis >> Electrical >> Charging Systems >> Generator And Regulator >> Specifications >> General Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

General Specifications

Item Specification
2.3L EcoBoost (199kW/270PS) - 210 amps 
Rating 210 amps
Generator amps at 80.6deg.F (27deg.C) 130 amps at 750 rpm (min) to 220 amps at 2, 500 rpm (max)
Generator pulley ratio 2.6:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.7L EcoBoost (238kW/342PS) - 210 amps 
Rating 210 amps
Generator amps at 80.6deg.F (27deg.C) 85 amps at 580 rpm (min) to 220 amps at 2, 300 rpm (max)
Generator pulley ratio 2.7:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
2.3L EcoBoost (199kW/270PS) - 250 amps 
Rating 250 amps
Generator amps at 80.6deg.F (27deg.C) 145 amps at 750 rpm (min) to 250 amps at 2, 500 rpm (max)
Generator pulley ratio 2.6:1
Generator pulley replaceable Yes
Generator pulley type Overrunning Alternator Decoupler (OAD)
Voltage regulator type Electronic internal with generator
2.7L EcoBoost (238kW/342PS) - 250 amps 
Rating 250 amps
Generator amps at 80.6deg.F (27deg.C) 95 amps at 580 rpm (min) to 250 amps at 2, 300 rpm (max)
Generator pulley ratio 2.7:1
Generator pulley replaceable No
Generator pulley type Solid
Voltage regulator type Electronic internal with generator
3.0L EcoBoost (299kW/406PS) - 250 amps 
Rating 250 amps
Generator amps at 80.6deg.F (27deg.C) 110 amps at 625 rpm (min) to 250 amps at 2, 500 rpm (max)
Generator pulley ratio 2.67:1
Generator pulley replaceable Yes
Generator pulley type One way clutch (OWC)
Voltage regulator type Electronic internal with generator