| B1A01:01 |
Speaker #1: General Electrical Failure |
GO to Pinpoint Test C |
| B1A01:11 |
Speaker #1: Circuit Short To Ground |
GO to Pinpoint Test C |
| B1A01:12 |
Speaker #1: Circuit Short To Battery |
GO to Pinpoint Test D |
| B1A01:13 |
Speaker #1: Circuit Open |
GO to Pinpoint Test D |
| B1A02:01 |
Speaker #2: General Electrical Failure |
GO to Pinpoint Test N |
| B1A02:11 |
Speaker #2: Circuit Short To Ground |
GO to Pinpoint Test N |
| B1A02:12 |
Speaker #2: Circuit Short To Battery |
GO to Pinpoint Test O |
| B1A02:13 |
Speaker #2: Circuit Open |
GO to Pinpoint Test O |
| U0100:00 |
Lost Communication With ECM/PCM 'A': No Sub Type Information |
GO to Pinpoint Test E |
| U0140:00 |
Lost Communication With Body Control Module: No Sub Type Information |
GO to Pinpoint Test F |
| U0422:00 |
Invalid Data Received From Body Control Module: No Sub Type Information |
GO to Pinpoint Test G |
| U201A:51 |
Control Module Main Calibration Data: Not Programmed |
GO to Pinpoint Test J |
| U202B:61 |
In-Use Application Signing Key: Signal Calculation Failure |
GO to Pinpoint Test H |
| U202B:62 |
In-Use Application Signing Key: Signal Compare Failure |
GO to Pinpoint Test I |
| U2101:00 |
Control Module Configuration Incompatible: No Sub Type Information |
GO to Pinpoint Test J |
| U3000:41 |
Control Module: General Checksum Failure |
GO to Pinpoint Test K |
| U3000:42 |
Control Module: General Memory Failure |
GO to Pinpoint Test K |
| U3000:96 |
Control Module: Component Internal Failure |
GO to Pinpoint Test K |
| U3003:16 |
Battery Voltage: Circuit Voltage Below Threshold |
GO to Pinpoint Test L |
| U3003:17 |
Battery Voltage: Circuit Voltage Above Threshold |
GO to Pinpoint Test M |