LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2023 >> Escape ST-Line Select >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Electronic Engine Controls - 2.0L ECOBOOST (177KW 240PS) - Mi4 >> Specifications >> Typical Diagnostic Reference Values
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Typical Diagnostic Reference Values

NOTE: Footnotes are referenced throughout the Typical Diagnostic Reference Value Charts. A letter in parentheses next to a value indicates supplemental information is available.

An attempt is made to provide as much information as possible. Some vehicles may not display all input and output signals.

The Typical Diagnostic Reference Value Charts do not display fault parameter identifications (PIDs). These are PIDs which indicate a hard fault with the circuit. They display a value of FAULT or NO FAULT and are PIDs ending with the letter F.

Reference values may vary 20% depending on operating conditions, altitude, and other factors. The RPM values are axle and tire dependent.

Values are taken at an altitude of approximately 189 meters (620 ft) above sea level with the engine at normal operating temperature and accessories off.

For detailed transmission diagnostics, refer to the Service Informatio. Transmission signals may be referred to in either alpha or numeric form. For example, 1=A, 2=B, 3=C.

PID Units Measured/PID Component/PID Only Measured/PID Values
KOEO Hot Idle 48KM/H (30 MPH) 89 KM/H (55 MPH)
PCM AAT (Deg C) DEG C (DEG F) AAT Sensor 1 (33.8) 1 (33.8) 1 (33.8) 1 (33.8)
PCM AAT_V (V) VOLTS AAT Sensor 3.78 3.78 3.85 3.88
PCM AC_REQUEST YES/NO PID NO NO NO NO
PCM APP (%) % APP Sensor 0 0 10 14
PCM APP1 (V) VOLTS APP Sensor 0.81 0.81 1.12 1.25
PCM APP1_[APP_D] (%) % APP Sensor 16 16 22 25
PCM APP2 (V) VOLTS APP Sensor 0.41 0.41 0.57 0.63
PCM APP2_[APP_E] (%) % APP Sensor 8 8 11 13
PCM APP_MAXDIFF (Deg) DEG PID 0.00 0.00 0.00 0.00
PCM BARO (kPa) kPa (PSI) PID 99 (14.36) 99 (14.36) 99 (14.36) 99 (14.36)
PCM BARO_V (V) VOLTS PID 3.87 3.87 3.87 3.86
PCM BATT_V_INF (V) VOLTS PID 12.65 14.96 14.96 14.96
PCM BOOSTP_EVAL YES/NO PID YES YES YES YES
PCM BRKOVRD_POSS NUMERIC VALUE PID 9 9 9 9
PCM BRKOVR_ACTION NUMERIC VALUE PID 0 0 0 0
PCM CAC_T (Deg C) DEG C (DEG F) CACT Sensor 0 (0) 0 (0) 0 (0) 0 (0)
PCM CAM_SYNC YES/NO PID NO YES NO NO
PCM CATTEMP11 (Deg C) DEG C (DEG F) CAT11 Sensor 536 (996.8) 548 (1, 018.4) 579 (1, 074.2) 673 (1, 243.4)
PCM CHT (Deg C) DEG C (DEG F) CHT Sensor 82 (179.6) 85 (185) 85 (185) 87 (188.6)
PCM CHT2 (Deg C) DEG C (DEG F) CHT2 Sensor 100 (212) 97 (206.6) 101 (213.8) 106 (222.8)
PCM CHT2_V (V) VOLTS CHT2 Sensor 3.41 3.50 3.36 3.19
PCM CLRDIST (km) KM (MILES) PID 0.0 (0.0) 0.0 (0.0) 0.0 (0.0) 2.0 (1.24)
PCM CYL1_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCM CYL2_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCM CYL3_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCM CYL4_ACCL NUMERIC VALUE PID (I) -1 TO +1 -1 TO +1 -1 TO +1
PCM DECHOKE YES/NO PID YES NO NO NO
PCM DIST_AEIS (km) KM (MILES) PID 0.0 (0.0) 0.0 (0.0) 0.0 (0.0) 0.0 (0.0)
PCM DIST_BRKOVRD (km) KM (MILES) PID 9.5 (5.90) 9.5 (5.90) 10.0 (6.21) 11.5 (7.15)
PCM DPFE_PRES (kPa) kPa (PSI) Differential Pressure Feedback EGR Sensor -0.14 (-0.02) -0.39 (-0.06) -0.14 (-0.02) 3.88 (0.56)
PCM DPFE_V (V) VOLTS Differential Pressure Feedback EGR Sensor 1.49 1.48 1.49 1.61
PCM DTCCNT NUMERIC VALUE PID 0 0 0 0
PCM DTCCNT_OBD NUMERIC VALUE PID 0 0 0 0
PCM EBP (kPa) kPa (PSI) EBP Sensor 100.14 (14.52) 99.42 (14.42) 102.33 (14.84) 101.69 (14.75)
PCM EBP_V (V) VOLTS EBP Sensor 0.98 1.06 0.95 0.93
PCM ECT (Deg C) DEG C (DEG F) ECT Sensor 71 (159.8) 70 (158) 79 (174.2) 86 (186.8)
PCM ECT1_V (V) VOLTS ECT Sensor 0.98 1.00 0.78 0.64
PCM EGRT_B (Deg C) DEG C (DEG F) EGRT12 Sensor -19 (-2.2) -19 (-2.2) -13 (8.6) -8 (17.6)
PCM EGRT_B_V (V) VOLTS EGRT12 Sensor 0.91 0.92 0.44 0.28
PCM EGRVP (V) VOLTS EGR Valve 0.91 0.91 1.13 1.20
PCM EGRVPDES (%) % PID 0 0 49 49
PCM EGR_A_ACT (%) % EGR Valve 0 0 7 10
PCM EGR_A_CMD (%) % PID 0 0 7 10
PCM EQ_RAT11 RATIO PID 0.00 1.02 1.03 1.08
PCM ETC_ACT (Deg) DEG PID 12.49 3.47 9.79 11.37
PCM ETC_TRIM (Deg) DEG PID 0.14 (E) 0.15 (E) 0.16 (E) 0.16 (E)
PCM ETC_[TAC_PCT] (%) % PID 9 4 11 13
PCM EVAP020C YES/NO PID NO NO NO NO
PCM EVAPCP (%) % EVAPCP Valve 0 6 50 13
PCM EVAPCV (%) % CANV Valve 0 0 0 0
PCM EVAPPCT (%) % PID 0 6 50 13
PCM EVAPSOAK YES/NO PID NO NO NO NO
PCM EVAPSTA STATUS PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING
PCM EVBV (% Duty Cycle) % EVAP Vapor Blocking Valve 0 0 100 100
PCM FAN_DSD (%) % PID 8 8 8 8
PCM FLI (%) % Fuel Level Sensor 44 (B) 45 (B) 46 (B) 44 (B)
PCM FLP (kPa) kPa (PSI) Fuel Pressure Sensor 612 (88.76) 547 (79.34) 546 (79.19) 548 (79.48)
PCM FLP_DSD (kPa) kPa (PSI) Fuel Pressure Sensor 546 (79.19) 546 (79.19) 546 (79.19) 546 (79.19)
PCM FLP_V (V) VOLTS Fuel Pressure Sensor 3.97 3.57 3.57 3.58
PCM FP (%) % Fuel Pump Control Module 75 26 26 26
PCM FPM (%) % PID 40 40 40 40
PCM FRP (kPa) MPa (PSI) FRP Sensor 7.11 (1, 031.22) 4.93 (715.01) 7.50 (1, 087.78) 7.88 (1, 142.90)
PCM FRP_DSD (kPa) MPa (PSI) PID 0.430 (62.37) 4.96 (719.39) 7.69 (1, 115.34) 7.90 (1, 145.80)
PCM FRP_V (V) VOLTS FRP Sensor 1.31 1.06 1.37 1.40
PCM FRT_A_RAW (Deg C) DEG C (DEG F) FRPT Sensor 16 (60.8) 16 (60.8) 16 (60.8) 16 (60.8)
PCM FRT_V (V) VOLTS FRT Sensor 0 0 0 0
PCM FTP_V (V) VOLTS FTP Sensor 2.63 2.47 2.39 2.45
PCM FUELSYS_CL YES/NO PID NO YES YES YES
PCM FUELSYS_OL YES/NO PID NO NO NO NO
PCM HFC ON/OFF PID OFF OFF OFF OFF
PCM HTR11 ON/OFF HO2S11 Sensor OFF ON ON ON
PCM HTR12 ON/OFF HO2S12 Sensor OFF ON ON ON
PCM HTR21 ON/OFF HO2S21 Sensor OFF OFF OFF OFF
PCM HTR22 ON/OFF HO2S22 Sensor OFF OFF OFF OFF
PCM HTRCM11 (Amp) mA HO2S11 Sensor 0.00 0.00 0.00 0.00
PCM HTRCM12 (Amp) mA HO2S12 Sensor 0.00 0.00 0.00 0.00
PCM IAT (Deg C) DEG C (DEG F) IAT Sensor 37 (98.6) 26 (78.8) 24 (75.2) 20 (68)
PCM IAT11 (Deg C) DEG C (DEG F) IAT Sensor 37 (98.6) 26 (78.8) 23 (73.4) 20 (68)
PCM IAT12 (Deg C) DEG C (DEG F) IAT2 Sensor 33 (91.4) 30 (86) 26 (78.8) 14 (57.2)
PCM IAT1_V (V) VOLTS IAT Sensor 1.89 2.39 2.50 2.68
PCM IAT2 (Deg C) DEG C (DEG F) IAT2 Sensor 33(91.4) 30 (86) 26 (78.8) 24 (75.2)
PCM IAT2_V (V) VOLTS IAT2 Sensor 2.06 2.17 2.39 2.45
PCM INJ1_F YES/NO PID NO NO NO NO
PCM INJ2_F YES/NO PID NO NO NO NO
PCM INJ3_F YES/NO PID NO NO NO NO
PCM INJ4_F YES/NO PID NO NO NO NO
PCM INJECTOR_OFF -----/DISABLE Injector 1-4 ----- ----- ----- -----
PCM KNK_CNTR_CYL1 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL2 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL3 COUNT PID 0 0 0 0
PCM KNK_CNTR_CYL4 COUNT PID 0 0 0 0
PCM KNOCK_1 COUNT KS11 Sensor 999 81 69 89
PCM KNOCK_2 COUNT KS12 Sensor 999 85 82 100
PCM LOAD (%) % PID 0.00 (A) 41 40 29
PCM LOAD_ABSL (%) % PID 0.00(A) 23 36 43
PCM LONGFT1 (%) % PID (A) -20 TO +20 -20 TO +20 -20 TO +20
PCM MAP (kPa) kPa (PSI) MAP Sensor 99.00 () 38.50 () 68.00 () 71.00 ()
PCM MAP_V (V) VOLTS MAP Sensor 1.52 0, 59 1.04 1.14
PCM MIL_DIS (km) KM (MILES) PID 0 (0) 0 (0) 0 (0) 0 (0)
PCM MIL_OBD ON/OFF PID OFF OFF OFF OFF
PCM MISFIRE TRUE/FALSE PID FALSE FALSE FALSE FALSE
PCM MP_LRN TRUE/FALSE PID TRUE TRUE TRUE TRUE
PCM NUM_MISFIRE COUNT PID 0 0 0 0
PCM O2S11_CUR (mA) mA/uA HO2S11 Sensor (A) switching (C) switching (C) switching (C)
PCM O2S11_HTR (%) % HO2S11 Sensor 20 24 25 24
PCM O2S11_IMPED (V) VOLTS HO2S11 Sensor 5.00 0.17 0.17 0.17
PCM O2S11_READY YES/NO HO2S11 Sensor NO YES YES YES
PCM O2S12 (V) VOLTS HO2S12 Sensor (A) switching (D) switching (D) switching (D)
PCM O2S21_READY TRUE/FALSE HO2S21 Sensor NO YES YES YES
PCM O2_DS_DISBL TRUE/FALSE PID TRUE FALSE FALSE FALSE
PCM OCTADJ_R_LRND % PID 0 0 0 0
PCM PATSENABL ENABLED / DISABLED PID ENABLED ENABLED ENABLED ENABLED
PCM RO2FT1 (%) % PID 0.00 0.00 -0.01 0.03
PCM RPM (Rpm) RPM CKP Sensor 0 751 1954 1839
PCM RPM_DSD (Rpm) RPM PID 750 750 750 750
PCM SHRTFT1 (%) % PID (I) -10 TO +10 -10 TO +10 -10 TO +10
PCM SPARKADV (Deg) DEG PID 10.00 9.00 19.00 13.5
PCM SYNC YES/NO PID NO YES YES YES
PCM TCBP (kPa) kPa (PSI) TCBP Sensor 96.7() 96.9() 97.8 () 113.6()
PCM TCBP_V (V) VOLTS TCBP Sensor 1.42 1.42 1.43 1.65
PCM TP1_LRN_TRIM (Deg) DEG ETBTPS 6.13 6.13 6.13 6.13
PCM TP1_PER (%) % ETBTPS 18 9 14 27
PCM TP2_LRN_TRIM (Deg) DEG ETBTPS 0.00 0.00 0.00 0.00
PCM TP_REL (%) VOLTS PID 12 3 7 20
PCM TURBO_BP1_STAT FAULT/NO FAULT TCBY Valve NO FAULT NO FAULT NO FAULT NO FAULT
PCM TURBO_BPASS (%) % TCBY Valve 0 0 0 0
PCM TURBO_WGATE (%) % Turbocharger Wastegate Control 0 0 0 0
PCM VCTSYS ENABLED / DISABLED PID DISABLED ENABLED ENABLED ENABLED
PCM VCT_EXH_ACT1 (Deg) DEG PID 0.00 -0.25 30.31 19.94
PCM VCT_EXH_DC1 (%) % VCT12 Solenoid 0 0 41 35
PCM VCT_EXH_DIF1 (Deg) DEG PID 0.00 0.25 3.75 0.00
PCM VCT_INT_ACT1 (Deg) DEG PID 0.00 0.25 -11.19 -34.38
PCM VCT_INT_DC1 (%) % VCT11 Solenoid 0 0 32 39
PCM VCT_INT_DIF1 (Deg) DEG PID 0.00 -0.25 3.44 -0.38
PCM VPWR (V) VOLTS PID VBAT VBAT VBAT VBAT
PCM VREF (V) VOLTS PID 5 5 5 5
PCM VSS (Kph) km/h (MPH) PID 0 (0) 0 (0) 48 km/h (30 MPH) 89 km/h (55 MPH)
PCM WGATE_A_POS_PCT (% Open) % Turbocharger Wastegate Motor 1 32.76 0.00 43.20 95.82
PCM WGATE_A_V (V) VOLTS Wastegate Position Sensor 1 2.45 1.58 2.70 4.09