| Item | Specification |
|---|---|
| 2.3L EcoBoost - Limited and XLT with trailer tow vehicles built before October 2020 | |
| Rating | 220 amps |
| Generator amps at 80.6°F (27°C) | 117.9 amps at 700 rpm (min) to 231.1 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.44 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 2.3L EcoBoost - Base, XLT and Timberline vehicles built after October 2020 | |
| Rating | 150 amps |
| Generator amps at 80.6°F (27°C) | 94.7 amps at 750 rpm (min) to 134.7 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.76 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 2.3L EcoBoost - Limited vehicles built after June 2021 | |
| Rating | 200 amps |
| Generator amps at 80.6°F (27°C) | 108.5 amps at 700 rpm (min) to 219.3 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.44 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.0L EcoBoost - All except police vehicles built before October 2020 | |
| Rating | 220 amps |
| Generator amps at 80.6°F (27°C) | 112.6 amps at 625 rpm (min) to 233.7 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.69 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.0L EcoBoost - All ST vehicles built after October 2020 | |
| Rating | 220 amps |
| Generator amps at 80.6°F (27°C) | 112.6 amps at 625 rpm (min) to 233.7 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.69 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.0L EcoBoost - King Ranch. Platinum vehicles built after June 2021 | |
| Rating | 200 amps |
| Generator amps at 80.6°F (27°C) | 95.1 amps at 625 rpm (min) to 184 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.69 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.0L EcoBoost - Police vehicles | |
| Rating | 250 amps |
| Generator amps at 80.6°F (27°C) | 103.3 amps at 625 rpm (min) to 226.5 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.69 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.3L Duratec - All except police vehicles | |
| Rating | 200 amps |
| Generator amps at 80.6°F (27°C) | 95.1 amps at 625 rpm (min) to 184 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.67 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |
| 3.3L Duratec - Police vehicles | |
| Rating | 250 amps |
| Generator amps at 80.6°F (27°C) | 106.5 amps at 625 rpm (min) to 199 amps at 2, 500 rpm (max) |
| Generator pulley ratio | 2.67 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Voltage regulator type | Electronic internal with generator |